background image

USA / FCC notice: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reaso-

nable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the installation manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged 

to try to correct the interference by one or more of the following measures:

-  Reorient or relocate the receiving antenna. 

 

 

 

 

 

 

-  Increase the separation between the equipment and receiver.

-  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

-  Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate this device.

CANADIAN / ICES-003 notification: 

This Device B digital apparatus complies with Canadian ICES-003.

Содержание EE381

Страница 1: ...Moisture in Oil Sensor BA_EE381 v05 Modification rights reserved 193021 User Manual EE381...

Страница 2: ......

Страница 3: ...ation 8 3 1 Installation Location 8 3 2 Installing the Probe directly into the Process 8 4 Electrical Connection 9 5 Operating Components 10 5 1 Circuit Board 10 5 2 Status LEDs 11 5 3 Display Module...

Страница 4: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by...

Страница 5: ...petition or forwarded to third parties Copies for personal use are permitted All information technical data and illustrations contained in these instructions are based on information available at the...

Страница 6: ...nmental Aspects Products from E E Elektronik are developed considering all important environmental issues While disposing of the product environmental pollution should be avoided To dispose of the sen...

Страница 7: ...istance to pollution of the E E HMC capacitive sensing elements series The sensor has two freely selectable and scaleable outputs for water activity temperature or water content in ppm The optional co...

Страница 8: ...ectly into the process there should be a stop valve on both sides of the point of installation This makes it easy to remove the sensor for maintenance and calibration Step 1 Install the probe with the...

Страница 9: ...User Manual EE381 Page 9 4 Electrical Connection Analogue output 1 7 6 5 2 3 4 1 V 2 GND 3 GND 4 OUT1 5 OUT2 6 NC 7 NC V mA V mA 10 30V DC 1 V 2 GND 10 30V DC...

Страница 10: ...e device Refer to chapter 5 2 Status LEDs 3 Current voltage output If the sensor is switched from current to voltage output using the configuration software the 2 jumpers must be positioned accordingl...

Страница 11: ...Power LED flashing supply voltage applied Yellow Red The yellow and red LEDs are deactivated and currently have no function 5 3 Display Module Option Measurand Units SI US T Temperature C F aw Water...

Страница 12: ...via LED on the circuit board Power LED green flashing Supply voltage applied Microprocessor is active LED D1 blue constantly lit sensing element damaged flashing sensing element bedewed condensation S...

Страница 13: ...ply voltage Check wiring and supply voltage Green LED is illuminated continuously electronics defect contact the manufacturer Further self diagnosis i Error possible cause measures help 6 3 Replacemen...

Страница 14: ...Temperature dependence aw 0 00022 0 0002 x aw x T C T T 20 C T 0 0003 C C Response time t90 in still oil at 20 C 68 F typ 10 min Temperature Oil temperature 40 120 C 40 248 F Accuracy Outputs Two free...

Страница 15: ...Stainless steel Working temperature range Probe 40 120 C 40 248 F Electronics 40 80 C 40 176 F Display 20 50 C 4 122 F Storage temperature range 40 60 C 40 140 F Electromagnetic compatibility accordi...

Страница 16: ...oulin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17...

Отзывы: