User Manual EE1900 Humidity Module for Climate Chambers

8  Replacement Parts / Accessories

See data sheet “Accessories” at www.epluse.com/EE1900

Description 

Order code

- Filter caps 

HA0101

xx

 

- Stainless steel grid 

 HA010109

 

- Stainless steel sintered

 HA010117

 

- PTFE

  

HA010105

 

- H

2

O

2

 HA010115

- Mounting flange stainless steel 

HA010201

- Mounting flange plastic 

HA010202

- Wall mounting clip stainless steel

 HA010225

- Wall mounting clip plastic -35...105 °C 

(-31...221 °F)

 

HA010211

Configuration cable with USB adapter

 HA011017

-

 

Humidity calibration kit 

see data sheet “Humidity calibration kit“

Protection cap for Ø12 mm (0.47") probe

 HA010783

9  Technical Data

Sensing element 

HMC01

Measurands

Relative humidity (RH)

Working range 

0…100% RH

 Accuracy

1)

 (incl. 

hysteresis, non-linearity and repeatability

)

 

-20...40 °C 

(-4...104 °F)

 

± 2%  RH (

90% RH)  /  ± 2.5% RH (>90% RH)

 

-40...180 °C 

(-40...356 °F)

 

± 2.5%  RH (

90% RH)  /  ± 3.5% RH (>90% RH)

Dew point (Td)

Working range 

-20...80 °C 

(-4...176 °F)

Accuracy 

± 2 °C 

(± 3.6 °F)

 

for | T

ambient

 - Td | < 20 °C 

(36 °F)

General

Response time RH t

10/90 

at 20°C 

(68 °F), 

typ. 

15 s with stainless steel grid filter

2)

  

Output signal 

0 - 1 / 5 / 10 V 

-1 mA < I

L

 < 1 mA 

 

0 / 4 - 20 mA (3 wire)  R

L

 < 500 Ω 

ARC status signal 

Optocoupler, open/closed

Supply voltage 

15 - 35 V DC and 17 - 29 V AC

Current consumption 

 

for DC supply  

< 32 mA 

 

for AC supply  

< 60 mA

rms

Working range electronics 

-40…60 °C 

(-40...140 °F) 

/  0...90% RH non-condensing

Working range probe 

-70...180 °C 

(-94...356 °F) 

/  0...100 % RH

Storage conditions 

-40…60 °C 

(-40...140 °F) 

/  0...90% RH non-condensing

Electrical connection 

Screw terminals up to max. 1,5 mm

² 

(AWG 16)

 

Electromagnetic compatibility 

Component for OEM equipment tested 

according to 

 

 

 

EN 61000-4-3 and EN 61000-4-6

  

1)

  The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was 

  

  calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).

   

2)  Other filters see data sheet “Accessories”.

Содержание EE1900

Страница 1: ...BA_EE1900 v1 1 Modification rights reserved User Manual EE1900 HUMIDITY MODULE FOR CLIMATE CHAMBERS...

Страница 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Страница 3: ...al 5 2 1 1 Sensing Probes 6 2 1 2 Filter Caps 6 2 2 Dimensions 6 2 3 Installation 6 2 3 1 Electronics Board 6 2 3 2 Sensing Probe 6 3 Electrical Connection 7 4 Setup and Configuration 8 4 1 Selection...

Страница 4: ...commissioning shall be performed by qualified personnel only 1 2 2 Mounting Start up and Operation The device has been produced under state of the art manufacturing conditions has been thoroughly test...

Страница 5: ...E E Elektronik are developed and manufactured observing of all relevant requirements with respect to environment protection Please observe local regulations for the device disposal For disposal the i...

Страница 6: ...47 Probe length see ordering guide Cable length see ordering guide Filter length see table below 3 5 0 14 3 5 0 14 Fig 1 Dimensions of EE1900 2 3 Installation ESD handling regulations must be strictly...

Страница 7: ...tor If the probe is installed into a partition wall the probe s backend shall be isolated thermally 3 Electrical Connection Supply Fig 2 Power supply 15 35 V DC 17 29 V AC Connection supply and output...

Страница 8: ...RH and error indication according NAMUR see chapter 4 3 is disabled After switching the output between voltage and current with the slide switch the scaling of the output can be set using the E E Pro...

Страница 9: ...manually by pressing the Sensor Recovery button No 6 Fig 3 for min 3 seconds or automatically by applying a voltage of 5 30 V DC to the potential free input No 3 Heat IN Fig 3 for at least 3 seconds A...

Страница 10: ...overy The ARC mode is indicated by the closed contact at the optocoupler output No 3 Status Fig 3 and by the red LED flashing very quickly The optocoupler output thus indicates wether the data on the...

Страница 11: ...guration PC HA011017 EE1900 The adjustment shall be performed for the RH output against an appropriate RH reference See Calibration Kit User Guide at www epluse com ee1900 7 Self Diagnosis and Error M...

Страница 12: ...RH Dew point Td Working range 20 80 C 4 176 F Accuracy 2 C 3 6 F for Tambient Td 20 C 36 F General Response time RH t10 90 at 20 C 68 F typ 15 s with stainless steel grid filter2 Output signal 0 1 5...

Страница 13: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Отзывы: