15
UG 6980 / 02.09.16 en / 756
Your Advantage
•
Adjustable safety functions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
•
Manual or auto start
•
Only one device, different safety functions
Features
•
According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
•
Acc. to EN 50156-1 for furnaces
•
Line fault detection on On-button:
•
Manual restart or automatic restart
•
With or without cross fault monitoring
•
2-channel
•
Forcibly guided output contacts
•
Output: max. 4 NO instantaneous semiconductor monitoring output
•
LED indicator for operation, delay contects and failure
•
As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
•
Width: 22.5 mm
0269011
For enable and interrupt a safety circuit in a safe way. It can be used to
protect people and machines in applications with e-stop buttons, safety
gates, light curtains with selftesting (Type 4) acc. to IEC/EN 61 496-1,
2-hand controls for presses as well as other production machinery with
dangerous closing action (Type III C to EN 574) and for safety mats, safety
edges and tape switches with a max. switching current of 15 mA.
green LED ON:
on, when supply connected
red LED ERR:
on, at internal error
flashes at external error
green LED K1/K2 (.02)
e.g. K1-K4 (.04):
on, when relay K1 and K2 (.02)
energized, e.g. when relay
K1, K2, K3 and K4 (.04) energized
flashes at external error
S12
A2
14
GND
S11
A1+
13
RES
S21
ST1
23
ST2
S22
38
24
M10562
13
K1
K2
23
14 24
K1/K2
+
38
Terminal designation
Signal designation
A1 +
DC 24 V
A2
0 V
13, 14, 23, 24,
43, 44, 53, 54
Forcibly guided NO contacts for
release circuit
38
Semiconductor monitoring output
GND
Reference potential for
Semiconductor monitoring output
S11, S21
control output
S12, S22, ST1, ST2, RES
control input
UG 6980.02
S12
A2
14
GND
S11
A1+
13
RES
S21
ST1
23
ST2
S22
38
24
M11127
13
K1
K2
23
14 24
K1-K4
+
38
44
43
53 54
43
K3
K4
53
44 54
UG 6980.04
Canada / USA
The multifunctional safety module UG 6980 provides protection of men
and machines by enabling and disabling a safety circuit. It is used together
with e-stop buttons, safety gates, light curtains with self testing (type 4)
to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and
productions machines with dangerous closing movements (type III C to
EN 574) and safety mats, edges and tape switches. Simply select 1 out of
5 safety functions on rotary switches - ready. This reduces divers types of
safety modules in stock and simplifies your disposition.
Safety Technique
SAFEMASTER C
Multifunctional Safety Module
UG 6980
Product Description
Circuit Diagram
Connection Terminals
Approvals and Markings
Application
Indicators
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
Содержание SAFEMASTER C UG 6980
Страница 4: ...4 UG 6980 02 09 16 de 756...
Страница 14: ...14 UG 6980 02 09 16 en 756...
Страница 24: ...24 UG 6980 02 09 16 fr 756...
Страница 35: ...35 UG 6980 02 09 16 de en fr 756 DE Notizen EN Notice FR Note...