background image

 

© Copyright e-con Systems. 2017. All rights reserved. 

 

13 

Troubleshooting

 

In this section, you can view the list of commonly occurring issues and their 
troubleshooting steps. 

Device connected, indication LED is RED, and the device is not listed in the 
application or device manager. 

It seems like device firmware is corrupted. You need to try re-flashing firmware 
image using firmware updater application from developer website. If this does not 
help, contact e-con Systems online support 

[email protected]

. 

The application displays a Firmware Download Failed! message during the 
firmware update process. 

It seems like you have removed the device in the middle of firmware update process 
or this is due to a bad USB connection. Do not disturb the USB connection or unplug 
the camera when the firmware update is in process. Please retry Step 1 - Device 
Selection 
to Step 4 - Firmware Update Complete for firmware update process. 

Содержание See3CAM 130

Страница 1: ...See3CAM_130 Version 1 1 e con Systems 6 1 2017 DFU Application User Manual ...

Страница 2: ... Copyright e con Systems 2017 All rights reserved 1 Disclaimer e con Systems reserves the right to edit modify this document without any prior intimation of whatsoever ...

Страница 3: ...ME SCREEN 4 STEP 2 INSTALLATION PATH SELECTION 4 STEP 3 READY TO INSTALL WINDOW 5 STEP 4 ATTACHING THE DEVICE 5 USING THE SEE3CAM_DFU APPLICATION 7 STEP 1 DEVICE SELECTION 7 STEP 2 FIRMWARE SELECTION 8 STEP 3 FIRMWARE UPDATE PROCESS 8 STEP 4 FIRMWARE UPDATE COMPLETE 10 TROUBLESHOOTING 13 FAQ 14 WHAT S NEXT 16 GLOSSARY 17 SUPPORT 18 ...

Страница 4: ...e will be released which has additional features that are supported in the See3CAM device Please refer to Firmware Release Notes to know about additional features The new firmware also includes bug fixes and hence it is essential to upgrade this firmware to avail the new features of See3CAM device This document highlights the process of updating a new firmware in the See3CAM product In future to a...

Страница 5: ...1 Welcome Screen As a first step double click the See3CAM_DFU application setup file The files required are extracted and you can view the Welcome screen as shown below Figure 1 Welcome Screen Click the Next button to go to the next screen Step 2 Installation Path Selection To select the installation path you can either use the default installation path C Program Files e con Systems See3Cam_DFU or...

Страница 6: ...election Window Step 3 Ready to Install Window To begin the installation you can click the Install button as shown below Figure 3 Ready to Install Window Step 4 Attaching the Device After the installation of See3CAM_DFU application you can view the completion window as shown below ...

Страница 7: ...6 See3CAM_130 DFU Application User Manual Figure 4 Completion Window When you click the Finish button you can exit the Setup Wizard and the See3CAM device will be attached to the PC ...

Страница 8: ...Firmware Update Complete Step 1 Device Selection Click the Device drop down list which lists all the devices connected to the PC and select the device to update the firmware If the device is connected to update the firmware Device is Connected label will be displayed In this case the device connected is See3CAM_130 VID_2560 PID_C0D0_0 as shown below Figure 5 Device Selection If no devices are conn...

Страница 9: ...wse button and select the firmware image as shown below Figure 7 Firmware File Selection Window You can verify the product name and firmware version before proceeding To view the firmware image click the Open drop down list as shown in above image Step 3 Firmware Update Process To select the firmware file click the Browse button as shown below ...

Страница 10: ... button to start the firmware update process You can switch the device to Firmware Update mode and can start erasing the Old Firmware as shown below Figure 9 Switching to Firmware Update Mode and Erasing the Old Firmware The application reads the firmware file and updates it into the device The progress of updating firmware is shown below ...

Страница 11: ...when the firmware update is in process Step 4 Firmware Update Complete Once the progress bar reaches 100 the device will automatically reset and gets detected with new firmware as shown below Figure 11 Firmware Update Complete You can click READ F W VERSION button to view the firmware version and check if the firmware is updated as shown below ...

Страница 12: ...ere is a bad USB connection or if you remove the device in the middle of firmware update then the application displays a Firmware Download Failed message as shown below Figure 13 Firmware Update Failure In this case the device is connected as e conDFU_USB_1_HUB_0 VID_2560 PID_DF00_0 as shown below ...

Страница 13: ...12 See3CAM_130 DFU Application User Manual Figure 14 Device in e con DFU Mode You can again follow the steps 1 to 4 to retry the firmware update process ...

Страница 14: ...age using firmware updater application from developer website If this does not help contact e con Systems online support support e consystems com The application displays a Firmware Download Failed message during the firmware update process It seems like you have removed the device in the middle of firmware update process or this is due to a bad USB connection Do not disturb the USB connection or ...

Страница 15: ...ur cameras simultaneously but unable to get a clear preview It might be due to bandwidth limitation issue Please try the following steps 1 Please disconnect other USB devices which are connected to the same host and connect only the USB camera and test it 2 Please use powered USB hub to overcome this issue 3 Please check in different desktop PCs in different USB ports 4 The output format of See3CA...

Страница 16: ...You could also observe this behaviour while switching the resolution of the camera 8 I am unable to view the images that were captured from the custom format cameras There are many free software tools available over the internet to view RAW images Please use IrfanView 7YUV and so on to view the RAW images that were captured from e con Systems custom format cameras 9 Do you have any sample applicat...

Страница 17: ...nual What s Next After understanding the usage of DFU application you can refer to the following documents to understand more about See3CAM_130 e CAMView Streaming Application User Manual of See3CAM_130 Firmware Release Notes of See3CAM_130 ...

Страница 18: ... Copyright e con Systems 2017 All rights reserved 17 Glossary USB Universal Serial Bus ...

Страница 19: ...cket for any type of issue please visit the ticketing page on our website https www e consystems com create ticket asp RMA To know about our Return Material Authorization RMA policy please visit the RMA Policy page on our website https www e consystems com RMA Policy asp General Product Warranty Terms To know about our General Product Warranty Terms please visit the General Warranty Terms page on ...

Страница 20: ...yright e con Systems 2017 All rights reserved 19 Revision History Rev Date Description Author 1 0 29 May 2017 Initial Draft Camera Dev Team 1 1 01 June 2017 Added changes for other See3CAMs Camera Dev Team ...

Отзывы: