4- SAFETY RULES AND WARNINGS
4.1- Safety Instructions
When a gas leak is found or suspected;
•
Turn off the gas valve of the boiler and the valves of all other devices operating with gas.
•
Shut off the stove, oven and similar appliances to put their flame out.
•
Do not light matches, lighter etc, and stub out your cigarette.
•
Ventilate the environment by opening doors and windows.
•
Do not ever touch the buttons and plugs of your electrical appliances.
•
Turn off the gas valves in the apartment and building entrance.
•
Do not use the phones at places where the gas leak is suspected.
•
Call your qualified person as soon as possible.
•
Do not place and use flammable and explosive liquid or materials around the boiler.
•
Keep materials such as water, foam away from electrical connections during operations such as cleaning,
gas leak test etc.
•
Do not lay the LPG container down
•
Do not block air vents, openings made in the walls of the room which provide fresh air to the installation
room.
4.2- Water Systems & Gas Supply Line
•
Before installation of the boiler, the water systems (CH & DHW circuit) and gas supply line must be
completed in accordance with the relevant regulations and standards by user.
4.3- Gas Type Conversion
•
The appliances should be purchased depending on operating gas type. In case of a demanding gas type
conversion, this is made with charge.
•
Gas type conversion should be performed by the authorized service. Gas leak test should be made after
the conversion operation.
•
The self-adhesive conversion label must br placed on the boiler after gas type conversion.
4.4- Installation
•
The boiler must be installed in accordance with national and local requirements, gas safety regulations,
relevant standarts and this manual by qualified installer.
•
The appliance should be mounted against a closed wall.
•
The appliance should not be positioned having direct contact to steam, detergent or gases.
•
Any change of flue position must not be made without consulting qualified person.
•
Sunlight can cause color change on the exterior of your device over time.
•
The device must be installed in indoor spaces under normal conditions. However, it can be operated in
a suitable cabinet in places such as garage, open balcony. Please consult E.C.A for proper cabine
sizes.
•
If device is located in an unheated area, it should be connected to mains, switched on, and pressure of
installation should be within operation range so that freeze protection would be activated. Even if device
is OFF position, freeze protection stays activated.
4.5- Boiler Start Up
• Boiler start up must be performed certainly by qualified person.
• Gas Type (Natural Gas / LPG), gas supply pressure (mbar), maximum DHW operating water pressure (bar) and
electricity supply voltage on the information plate must be suitable with mains supply conditions. This is checked
by qualified person.
•
After boiler start up, you should request information about operating the boiler and safety precautions
from qualified person.
CAUTION:
The 2-amp bipolar fuse with a minimum contact opening of 3 mm must be used
in the electrical connection of the boiler.
4
Содержание Proteus Premix PPR 14 HCH
Страница 9: ...5 4 Technical Specifications 9 ...
Страница 10: ...10 ...
Страница 11: ...5 5 Electrical Drawing Figure 4 Boiler sensor in HST model Except of HCH Model Only HM Model 11 ...
Страница 28: ...28 ...
Страница 29: ...Table 4 29 ...
Страница 32: ...16 INSTALLATION TEMPLATE 16 1 HM Model 32 ...
Страница 33: ...E E L C 160 mm 00 160 mm cJiD E E o o L C E 16 2 HCH Model 33 ...
Страница 34: ...E E L C 160 mm 00 C 160 mm E E o o L C E 16 2 HST Model 34 ...
Страница 36: ...36 ...
Страница 37: ...37 ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 41: ...41 ...