fig. 21
Programming the Unit
- Set the right sliding button to P.
- See the program number that you want to set while pressing P button. (If the program to be set is
startup program,
sign will appear. 1,3,5,7,9,11,13,15 are startup programs; 2,4,6,8,10,12,14,16 are
shutdown programs)
- Set the day of startup or shutdown program by pressing
button. (1:Monday, 2:Tuesday,
7:Sunday) Apart from one day setting, you can make settings for only workdays, only weekends and
all days except Sunday and for all days using this button.
- Set the hour by pressing h button.
- Set the minute by pressing m button.
- After setting startup and shutdown times, set the sliding button to RUN.
Ignoring the program
- If you want to turn off your unit while program is running or if you want to turn on the unit before
the program activates the device, press the
button. Pressing this button while device is running
turns off the unit. Pressing this button before program activates the unit, turns on the device
immediately, unit stops running at the end of program time. This button works only when sliding
button is at RUN position, and the button sign appears on display.
Manual
Control
- In order to control the unit manually use sliding button on the left of the clock. Unit runs
continuously while sliding button is at “I” position. Unit stops running when sliding button is at “0”
position. Unit runs according to program while sliding button is at “AUTO” position.
Resetting The Clock
-
In order to reset the clock, press R button while sliding button is at “RUN” position. All programs
set will be erased from the memory.
Programming On Winter Mode
-
Set your program on the program timer.
- Set the turn ON/OFF button to ON.
- Set the temperature thermostat to any level you wish.
- Your unit will turn itself on when the timer reaches to time you have set and system will keep the
temperature constant at the level you set. Unit will turn it self off when the timer reaches the time you
have set.
GAS TYPE CONVERSION
: Gas type conversion from LPG to natural gas or from natural gas toLPG
must be carried out only by qualified person.
-
Gas type conversion can be divided in 3 sections: 1-gas pressure adjustments, 2- replacement
of the burner injectors and 3-changing the parameter of the gas type (00-NG or 01-LPG).