Room Sealed Fan Assisted Operation
WARNING: For room sealed fan assisted appliance, the boiler location and air/flue
terminal position must obey national and local requirements, gas
safety regulations and relevant standarts.
The room sealed fan assisted boiler is not suitable for external installation. It should be
within in the building.
- In case of gas leakage, it is necessary to vent the installation room according to national and local
requirements, although the room sealed fan assisted boilers are independent of room volume and
ventilation.
WARNING: Do not block the air vents which provide fresh air to the installation room.
The air/flue terminal must be exposed to the external air and allow free passage of air cross it
at all times.
- The minumum acceptable dimensions from the terminal to obstructions and ventilation openings
must obey national and local requirements.
- The air/flue ducts should be fitted at a slight % 1
0
or 2
0
downwards incline to prevent any water or
condensation from entering the boiler.
Mounting The Boiler
Having determined the boiler location,
- Use the paper template to mark out the positions of the fixing holes of wall and mounting brackets.
- Drill the wall and fix the wall bracket to the wall with the 3 screws, then also the mounting bracket
with the 2 screws.
- Hang the boiler up on the wall bracket.
a)
b)