Definition
E.C.A. GP 11/13/16/20/24 kW Hermetic Combi (monothermic
model)
2.
SAFETY SYSTEMS
With the safety systems in your device, both you and your device are fully secured. These safety
systems;
Flame Loss Protection
Boiler Over-heat Safety System (105°C)
DHW (Domestic Hot Water) Over-heat Safety System (71°C)
CH (Central Heating Water) Over-heat Safety System (95°C)
High Water Pressure Protection System (3 bar)
Low Water Pressure Protection System (0,8 bar)
Low Voltage Protection System (165 V AC)
Thermal Accumulation Protection System (with by-pass circuit and pump over-run)
Frost Protection System (The appliance must be on stand-by to activate the frost
protection)
Water Flow Inspection.
Pump Dry Run Protection System
3 Way Valve Anti-sticking Function
Automatic Air Vent
Expansion Vessel (6L)
3.
GENERAL FEATURES
11 kW
13 kW
16 kW
20 kW
24 kW
Category
Type
Gas Inlet Pressure (Natural Gas G20)
mbar
Power
Unit
Pmin, heating power (thermal power)
kW
Pmax, heating power (thermal power)
kW
11,3
13
16
20
23,3
Qmin. Thermal Load
kW
Qmax. Thermal Load
kW
12,8
14,8
17,9
22,3
25,6
Gas Consumption
Unit
Natural Gas (at full power)
m
3
/h
1,38
1,58
1,93
2,41
2,76
Natural Gas (at min. power)
m
3
/h
NOx Class
Central Heating
Unit
Min. Water Pressure
bar
Max. Water Pressure
bar
Operation Range (@Radiator heating)
°
C
Operation Range (@Underfloor heating)
°
C
30 - 50
0,8
3
30 - 80
8,2
9,2
0,96
3
20
Unit
GP
Product Type
I
2H
C
12(X)
, C
32(X)
,*C
42(X)
,*C
52(X)