- Shut off the gas valve of the appliance and all of your gas burning appliance
- Shut off and put out your oven, stove, cooker etc.
- Do not light matches, lighters etc, put out your cigarettes.
- Open all your windows and door and ventilate the room.
- Do not switch on your electrical devices and do not touch the plugs.
- Shut off the gas valves at the building entrances.
- Do not use phones in the environments that have a gas smell.
- Call the gas company and inform the closest technical service.
- Do not put or use flammable materials near your appliance.
- Keep materials like water, foam etc. away from electrical connections during cleanup, maintenance
etc.
- Do not block ventilation outlets in your boiler room.
Fittings
- Before the installation of your boiler, natural gas, central heating and (if applicable) domestic hot
water pipings must be ready. Natural gas pipings must be designed, approved and done by a
qualified engineering office. All these must be done and paid by the user.
-
The appliance must be connected to a grounded plug with 230V AC, 50 Hz supply.
- Before the installation of your boiler, water circuit must be cleaned (power flushed) with suitable/
approved chemicals. To not damage the metal, plastic and rubber parts of the pipings and fittings,
use neutral based, non-acidic and non-alcalic cleaners. When using these chemicals, please follow
the instructions.
- Any dirt, blockages, welding residuals, burr, flug etc. particules left inside the pipes will affect the
boiler’s performance. These residuals will cause boiler to overheat, noisy operating etc. Any damage
or failure caused by unfit piping system is out of warranty coverage.
INFORMATION
If there is a natural gas smell;
SAFETY RULES
SAFETY RULES AND WARNINGS
2
Cascading Applications
While E.C.A. Felis boilers can be used as a single boiler, it can be used as a part of a cascading
system. Cascading system allows up to 16 boilers to work in coordination to reach capacities up
to 2400 kW.
Appliances in a cascading system are separated into two categories as master appliance and slave
appliances. All sensory information required for the heating system to perform is acquired and
processed by the master appliance and the resulting heat request information are sent to slave
appliances.
We strongly suggest that two ball valves should be installed to
the flow and return lines on the boiler water connection or
seperating the boiler from circuit when necessary.
This boiler is sold without the supplementary parts below due to the nature of the device. Capacity
and technical specifications of these parts will vary by the size of the heating system. All supplemen-
tary parts must be selected and fitted by a qualified plumber.
- Expansion vessel
- Pressure relief valve
- Circulation pump
- Water inlet valve
- Sludge catcher
- Air purger
- Hydraulic seperator
Содержание FELIS Series
Страница 1: ...FELIS WALL HUNG CONDENSING BOILER FELIS FL 50 65 100 125 150 HM INSTALLATION AND USER MANUAL...
Страница 2: ......
Страница 10: ...7 Felis 65 Figure 2b Felis 65 Detailed Drawings...
Страница 11: ...8 Felis 100 125 150 Figure 2c Felis 100 125 150 Detailed Drawings...
Страница 13: ...Figure 3 Electronic Board Circuit Diagram 10 Electrical Board Circuit Diagram...
Страница 18: ...d d l Figure 7 Flue Types 15 I I I I...
Страница 30: ...27...
Страница 31: ...28...
Страница 32: ...29...
Страница 33: ...30...
Страница 40: ......
Страница 46: ......