7- INSTALLATION
7.1 Selection of Location of Boiler
The boiler must be installed in accordance with relevant standards.
Additionally, the clearance around the boiler should be as shown in fig
1
2
. In order to make service,
maintenance and usage easier.
Figure 1
2
: It shows the minimum distances required from the top and sides of the boiler (Dimensions given
in mm).
The installation must comply with the following minimum distances so that servicing and maintenance of
the boiler can be performed correctly. The position of the boiler must be checked against technical
requirements.
Figure 1
2
.Combi Mounting Clearances
CAUTIONS :
Do not install your boilers in locations that will be exposed to direct sunlight. Sunlight can
cause color
change on the exterior of your boiler over time.
Ambient temperature of boiler's installation location should be between 5 -35
0
C.
The boiler can be used at altitudes up to 2000 m above sea level.
It is not recommended to install
“Isolating Valve Cover” (figure 1
3
-No 1
)
to the
boiler if kitchen cupboard is used for installation place. It can be used
at open
space areas to hide valve set and filling loop.
Upper side service space
Min. 500 mm.
Bottom side service
space
Min. 250 mm.
Left and right side
servicee space
Min. 150 mm.
22