41
COMMISSIONING
Fig 7-3
Fig 7-3
Fig 7-3
Fig 7-3
Fig 7-3
D
DD
DDual
ual
ual
ual
ual L
L
L
L
LCD Di
CD Di
CD Di
CD Di
CD Disssssppppplllllaaaaayyyyy w
w
w
w
with an option
ith an option
ith an option
ith an option
ith an optiona l
a l
a l
a l
a l 2nd 4-
2nd 4-
2nd 4-
2nd 4-
2nd 4-20 mA
20 mA
20 mA
20 mA
20 mA Outp
Outp
Outp
Outp
Output
ut
ut
ut
ut
Remove the screws to remove the adapter board. Carefully handle the adapter board and wiring to
avoid any damage. With the power supply off, connect the (+) side of the power supply to the (+)
OUT terminal of the electronics module. Connect the (-) side of the power supply through a 250
Ω
resistor to the (-) OUT terminal of the electronics module. See Figure 7-2. Connect the input
terminals 1 and 3 in series with the current loop to be measured. Terminal 1 should be more positive
than 3.
7.1.5
7.1.5
7.1.5
7.1.5
7.1.5
A
A
A
A
A
T
TT
TT
EMPERA
EMPERA
EMPERA
EMPERA
EMPERATURE
TURE
TURE
TURE
TURE
O
O
O
O
O
UTPUT
UTPUT
UTPUT
UTPUT
UTPUT
If the optional second 4-20 mA adapter board was ordered, the terminals 1 (+), 2 (-) on the adapter
board would also be connected to the 24 V dc power supply. This will provide the snout temperature
from the RTD in the process (located next to the diaphragm). Replace the display by aligning the
holes with pins and pushing the display gently into place. At this time you are ready for set-up using
the display, or the optional SmartLink software/modem or the optional HART 275 communicator.
7.1.5
7.1.5
7.1.5
7.1.5
7.1.5
B
B
B
B
B
4–20
4–20
4–20
4–20
4–20
M
M
M
M
M
A
A
A
A
A T
TT
TT
RANS
RANS
RANS
RANS
RANSMIT
MIT
MIT
MIT
MITTER
TER
TER
TER
TER
O
O
O
O
O
UTPUT
UTPUT
UTPUT
UTPUT
UTPUT
C
C
C
C
C
ABLE
ABLE
ABLE
ABLE
ABLE
The IPX II is supplied with a 11.5’ (3.5 m) cable for the transmitter output. A breakdown of the wiring
schematic is displayed in Table 7-2.