STEP 6 -
Option 1: Installing on a wood stud wall
Note
: Any drywall covering the wall must not exceed 5/8" (16 mm).
1
Locate the stud. Verify the center of the stud* with an edge-to-edge stud finder.
2
Align the wall plate template (
D
) at the height you determined in the previous step, make sure that it is
level, then tape it to the wall. Use a pencil to mark the lag bolt hole locations (4) on the stud centers.
3
Drill pilot holes to a depth of 3 in. (75 mm) using a 7/32 in. (5.5 mm) diameter drill bit. Remove the wall
plate template.
4
Align the wall plate (
A
) with the pilot holes, insert the lag bolts (
T
) through the lag bolt washers (
S
),
then through the holes in the wall plate. Tighten the lag bolts only until they are firm against the wall
plate.
CAUTION
: Avoid potential injuries or property damage! DO NOT over-tighten the lag bolts (
T
).
You’ll need
3 in.
(75 mm)
- Minimum wood stud size: common 51 x 102 mm (2 x 4 in.) nominal 38 x 89 mm (11/2 x 31/2 in.).
- Minimum spacing between horizontal fasteners cannot be less than16 in.
Edge-to edge
stud finder
T
(4)
Pencil
Drill
7/32" wood drill
bit
1/2" socket wrench
Level
S
(4)
V1 13-0671
Top / Dessus / Vista superior
Top / Dessus / Vista superior
Note:
For wood frame installations, use
Remarque :
Pour des installations sur
des structures en bois, utiliser d'abord
un localisateur de montants pour
détecter un montant en bois.
Nota:
para las instalaciones en marcos
de madera, use primero un localizador
de viga para ubicar las vigas de pared.
Important:
Make sure that the
lag bolts are inserted into a wood
stud. The distance between two
studs is typically 16".
Tools Needed
Outils nécessaires
Herramientas requeridas
DX-DRTVM114
Wall Plate Template • Gabarit de la plaque murale • Plantilla de la placa de pared
Wall plate template (
D
)
Tape
Wall plate (
A
)
DX-DRTVM114_13-0670_MAN_V1_ENG.fm Page 11 Monday, July 22, 2013 10:26 AM