A48100 Unit User Manual
16
Figure3-5
Figure3-6
(2)
Wall hanging Installation method:
Figure3-7
4. Install all screws according to the
hole position and there are
screws on the front and back
need to be fixed.
5. Stack the required number of battery and
bracket combinations as described above,
and fix the screws,twisting force keeps
9.8N·m.Shown as Figure3-6.
1. Use the positioning cardboard (provided
in accessory package) and mark the screw
hole positions on the wall, as shown on
the right.
2. The cardboard must be perpendicular to
the ground while drawing the holes.
3. The bottom of the cardboard is about
300mm from the ground.
4. According to the position of the mark, 8
holes in diameter 10mm and depth of
more than 70mm are hit on the wall with
an electric drill, which are used for fitting
expansion bolt M6.