O P E R A T I N G T I P S A N D T R O U B L E S H O O T I N G
Keep machine clean to ensure optimum performance. After each
use, lift off vacuum head and knock dust from filter. After one hour
of continuous use, lift out the Motorhead/Vacuum Head Assembly
and check the amount of dust accumulated in the unit. Remove the
dust bag if necessary and replace with a new one. We recommend
a soft brush to clean the filter.
DO NOT USE A BLOW GUN.
Decrease in Vacuum Performance
1.
Clean the filter thoroughly and as often as necessary. The
filter used inside is water resistant and washable. To prevent
damage, do not use high pressure or solvent to wash the filter.
2.
If the filter (P/N 80459) should become damaged or badly
clogged and cannot be cleaned, replace with a new one.
3.
Check all the vacuum lines for blockage or leakage.
Vacuum Stops During Use
1.
This vacuum is equipped with a Electronic Thermal Protection
Device. If the vacuum stops and the red indicator light appears
ON, the unit has shut down as a result of increased
temperature. Once the unit has regained a temperature that is
allowable for operation the vacuum will resume operation.
R E M O V A L / I N S T A L L A T I O N O F M O T O R H E A D F R O M M A I N A S S E M B LY
If the filter element becomes clogged or to clean the inner portions
of the drum (canister) the Motorhead Assembly must then be
removed to perform cleaning. When removal becomes necessary
for cleaning or other service, follow the procedures described
below.
Removal
1.
Unplug the unit before attempting service or maintenance work.
2.
Remove Top Lid by unlatching (2) hinges.
3.
Use a conventional vacuum cleaner to clean entire inside of
Motorhead/Vacuum Head Assembly and drum (canister).
Upon completion of the service work, install top lid according to
the following procedure:
Installation
1.
Place cleaned unit onto the drum (canister) and latch (2)
hinges to properly attach the lid. Unit is now ready for
operation.
T I LT - N - C L E A N O P E R A T I O N I N S T R U C T I O N
Unit has a Tilt-n-Clean feature to aid in overall functionality of the
work equipment and work environment:
1.
Unplug the unit before attempting service or maintenance
work.
2.
Unclamp and remove Motorhead/Vacuum Head Assembly.
Drum (canister) is now able to be tilted backwards and emptied.
Dispose of debris properly.
3.
Or, Pull side release hinges away from the drum (canister)
and remove the entire drum (canister) from the trolley. With
drum (canister) removed dispose of debris properly.
Содержание Raptor Vac