INSTRUCTIONS: QUASAR SV Code: DYN 64.1.06
Date: 08/11/2016 Revision: 06
4
For further information on the Quasar SV
’s tensioning devices, please refer to the Quasar-SV’s Tensioners manual.
4.3 REMOTE TRIPPING SYSTEM
The governor incorporates a remote jamming system to check for the correct interlocking of the governor and the
subsequent jamming of the safety gear.
It is basically made up of a remote electromagnetic interlocking system that may be operated from the machine room.
There are three versions available for the installer to choose at his/her convenience.
24 V
DC (Direct current) coil. A
1.2 A
intensity must be guaranteed.
48 V
DC (Direct current) coil. A
0.56 A
intensity must be guaranteed.
190 V
DC (Direct current) coil. A
0.16 A
intensity must be guaranteed.
4.4 OVERSPEED CONTACT
The governor incorporates an overspeed contact. Bearing in mind that the governor will be fitted in the car, this is an
automatic reset contact. In any case, after an interlocking, the lift must be started by a qualified person without having
to directly access the governor.
An image of the overspeed contact’s location is displayed below, where (1) is the automatic reset contact.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/