background image

INSTRUCTIONS: QUASAR SV   Code: DYN 64.1.06 

 

Date: 08/11/2016   Revision: 06   

8  INSTRUCTIONS FOR USE AND MAINTENANCE 

Tripping speed in the installation can be checked by operating on the motor’s frequency converter; progressively 
increasing the motor’s speed until interlocking occurs.  

To prevent unnecessary risks that may cause the incorrect operation of the governor, two essential criteria must be 
considered: Cleaning and monitoring against corrosion. There are mobile elements in any governor that will perform 
the interlocking operation. Dirt accumulation in these elements may cause malfunctioning. It is essential that both the 
installer and maintenance make sure that these components are perfectly clean. 

On the other hand, Dynatech governors have anti-corrosion protection in all the cases; however, it is important that 
maintenance checks if there is a corrosion process that may affect any mobile part of the component and may prevent 
its natural movement. This will be checked via visual inspection of the surfaces’ condition and acting consequently. 
The frequency of these check-

ups is left up to maintenance’s criterion; however, they must be more frequent in case 

the installation is in an especially corrosive environment.  

Dynatech cannot be held responsible for any problem or accident arising from the non-compliance of the orders and 
recommendations mentioned both in these instructions and in the documents concerning the EC type examination 
certificates. 

8.1  STORAGE AND SERVICE LIFE  

The overspeed governor must be stored in a cool, dry place. It must be protected from excessive light and never be 
exposed to the open air. 

Storage temperature: 5 - 40ºC. 

Storage Humidity: 15 - 85% without condensation 

Overspeed governor packages should be clean and dry so that they can be clearly identified. 

Constantly  leaning an unbalanced  load on packages, which may cause bending, or the accumulation of products 
stacked on top of each other is not allowed. When placing products or product packages on top of each other, the 
storage height should correspond to the packages’ load and stability. 

If the established criteria of this manual are observed, the overspeed governor’s service life is set by the wear of his 
main pulley groove, which depends on the installation duty cycle. When estimating the element’s service life, the 
effects of grease, dust or dirt due to the shaft’s condition or to environmental conditions differing from those stated in 
this manual, were not taken into consideration. 

9  INSTALLATION DRAWINGS 

The following drawings may be useful when adjusting and installing the QUASAR SV / QUASAR SV A3 overspeed 
governor: 

 

DYN 64.C001.00 

 

DYN 64.C002.00 

 

 

Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer 

area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/

Содержание QUASAR-SV

Страница 1: ...IDAD OVERSPEED GOVERNOR LIMITEUR DE VITESSE GESCHWINDIGKEITSBEGRENZER QUASAR SV INSTRUCCIONES DE USO Y MANUTENCI N INSTRUCTIONS FOR USE AND MAINTENANCE INSTRUCTIONS D USAGE ET ENTRETIEN GEBRAUCHS UND...

Страница 2: ......

Страница 3: ...STEM 4 4 4 OVERSPEED CONTACT 4 4 5 UCM UNCONTROLLED MOVEMENT DEVICE 5 4 5 2 UCM WARNINGS 5 5 FIXING THE GOVERNOR TO THE FRAME 6 6 TECHNICAL FEATURES 7 8 INSTRUCTIONS FOR USE AND MAINTENANCE 8 8 1 STOR...

Страница 4: ...r except for those parts specified in the manual DYNATECH DYNAMICS TECHNOLOGY SL will not be liable for any damage caused by failure to observe any of these general conditions 2 OVERSPEED GOVERNOR IDE...

Страница 5: ...the pit s ceiling and floor goes through the governor along its pulleys grooves This way the rope makes the pulley rotate and when the car reaches tripping speed the main pulley will rotate until the...

Страница 6: ...or rope but via an auxiliary mechanical system The following figure displays an example of this connection These parts are not supplied by the company DYNATECH DYNAMICS TECHNOLOGY S L They must be des...

Страница 7: ...A intensity must be guaranteed 48 V DC Direct current coil A 0 56 A intensity must be guaranteed 190 V DC Direct current coil A 0 16 A intensity must be guaranteed 4 4 OVERSPEED CONTACT The governor i...

Страница 8: ...ase with the D Box a levelling signal needs to be used Therefore if the car creeps with the doors open the sensor detects it and cuts off the current to the anti creep system coil thus locking the ove...

Страница 9: ...will lock and the safety gear subsequently engaged The installation of an autonomous power system is recommended to avoid undesired engagement in the event of a cut in the mains electricity supply Op...

Страница 10: ...re tensioning Via the spring tensioner devices the following are obtained Minimum tension 491N below this tension the contact cuts the safety line Maximum tension 745 N The tensioner plate s position...

Страница 11: ...ommendations mentioned both in these instructions and in the documents concerning the EC type examination certificates 8 1 STORAGE AND SERVICE LIFE The overspeed governor must be stored in a cool dry...

Страница 12: ...N QUASAR SV Escala CONJUNTO Sustituye a Sustituido por DYN 64 C001 00 OBSERVACIONES Material Peso terminado Tto tco Tto sup Fichero Fecha Nombre Dibujado Norma CANTIDAD POR CONJUNTO 287 5 210 35 5 72...

Страница 13: ...Escala Quasar SV CONJUNTO Sustituye a Sustituido por DYN 64 C002 00 OBSERVACIONES Material Peso terminado Tto tco Tto sup Fichero Fecha Nombre Dibujado Norma 20 03 2015 Pilar H CANTIDAD POR CONJUNTO 2...

Отзывы: