DynaQuip Controls • 10 Harris Industrial Park • St. Clair, MO 63077
Tel. 800-545-3636 • Fax. 636-629-5528  • www.watercop.com

Additional Components Available for Your WaterCop

®

 CLASSIC System

Installation Guide

IMPORTANT!

Adherence to all local and municipal building, plumbing and electrical codes as they pertain to the installation of the 

WaterCop

®

 CLASSIC System is of utmost importance . Codes in some areas may require that a licensed plumber be 

employed to do the installation, or that the proper permits be obtained prior to any installation . Even if local codes do not 

require a licensed plumber to do the installation, it is necessary that the installer has a professional level of competence 

in both plumbing and electrical skills to perform the installation . These instructions assume this level of knowledge and 

skill . If in doubt, use a licensed professional .

Pre-Installation Testing of WaterCop

®

Although each unit is pre-tested at the factory, it is highly recommended that the unit be tested prior to installation to 

ensure proper operation in your home . Operating the valve before connecting to the water line will not damage it .  

Use caution!

CAUTION!

   

  The valve closes with great force. It could cut off a finger. 

  •

  Keep fingers and other items out of the valve when testing. 

  WARNING!

 The WaterCop

®

 case is NOT EXPLOSION PROOF. The shut-off valve must NOT be  

installed where it could ignite flammable vapors or explosive mixtures. 

  WARNING! 

To reduce risk of electrical shock, fire, or damage to property or WaterCop

®

:  

  Do not use extension cords. Use of extension cords can cause fires or electric shock. Install  

WaterCop

®

 within 20 feet of an outlet or, install an outlet near the WaterCop

®

. Comply with  

all local codes. 

STOP

STOP

Single and Dual Probe WaterCop

®

 Flood Sensors

WCDFS1 

(single probe) and 

WCDFS2 

(dual probe)

  Battery or AC (optional) powered

   Transmits wireless signal to valve when moisture  

is detected

  Unlimited number can be used, placed anywhere

  10’ sensor cord, white

Low Temperature Sensor

WCDFST

  Monitors temperature of pipes prone to freezing

   Sends wireless signal to turn off water if low  

temperature detected

  10’ cord with clip to attach to pipe 

  Flood sensor with probe

Water Control Wall Switch

 RS100

   Proactively turn water on or off from convenient location

   Lighted display to valve position (on or off)

   Requires category 5E cabling connection to valve  

(see Wall Switch Interconnect Cable below)

AC Power Adaptor

   For WCDFS1, WCDFS2, and WCDFST sensors

   Eliminates the need for AA batteries

WaterCop

®

 / Wall Switch Interconnect Cable

 CBL50

 (50 feet) and 

CBL100

 (100 feet)

   Required to connect WaterCop

®

 valve with Water 

Control Wall Switch

   RJ45 molded connections for easy installation and 

durability

Содержание WaterCop classic

Страница 1: ...1 DynaQuip Controls 10 Harris Industrial Park St Clair MO 63077 Tel 800 545 3636 Fax 636 629 5528 www watercop com CLASSIC Owner s Manual Installation Guide...

Страница 2: ...llation Prodedure 9 Review Location and Type of Main Supply Line 9 Additional Part Requirements 10 Compression Fittings 10 Solder Fittings 11 Electrical Connection 11 Warnings and Precautions 11 Chang...

Страница 3: ...m TRANSMIT RECEIVE Range Enhancing Repeater DynaQuip Controls Inc St Clair MO www watercop com Water Sensor Transmitter DynaQuip Controls Inc St Clair MO www watercop com LISTED 57HM Range Enhancing R...

Страница 4: ...es The WaterCop valve should be installed in the main water line just downstream from the main shut off valve in your home The front control panel of the WaterCop should be easily visible in order to...

Страница 5: ...ets may disturb it The sensor probe should be placed FLAT on the floor so water can be detected as soon as it begins to accumulate The sensor probe may be secured to the floor with adhesive dots suppl...

Страница 6: ...interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful int...

Страница 7: ...of the valve when testing WARNING The WaterCop case is NOT EXPLOSION PROOF The shut off valve must NOT be installed where it could ignite flammable vapors or explosive mixtures WARNING To reduce risk...

Страница 8: ...below Manually Test the Flood Sensors Flood and Temperature sensors require power to operate Use either fresh AA alkaline batteries not included and or a WaterCop AC Adaptor sold separately to power I...

Страница 9: ...ire are clear of doors drawers sharp edges or other hazards that may cause damage Unplug the WaterCop after the testing is complete The WaterCop can now be installed Prior to installation read all war...

Страница 10: ...choice of fittings and methods of installation Compression Fittings Theunitcanbeinstalledwithcompressionfittingsusingcommonhouseholdtoolsandbasicmechanicalability Youwillneed a 2 fittings male pipe th...

Страница 11: ...c items we recommend plugging the WaterCop Actuator into a surge protector Warnings and Precautions WARNING The motorized drive unit case is not capable of supporting any loads Do not attempt to use t...

Страница 12: ...ts 5 6 and 7 are used to control the valve position from a remote location The most common is your home security system control panel This is done by wiring these contacts to a control switch on the p...

Отзывы: