D 9
D_E3
4_VB340_
05.
08_G
B.
fm
9-
26
- 01.
01.
07
3.4
Connection and leak test
The gas pipe system of the basic screed
and the extendable parts is permanently
installed. To connect the gas bottles:
- Unscrew the protective caps from the
bottle valves and screw onto the rear
of the bottle bracket.
- Check whether the quick action valves
are closed.
- Check that the bottle valves (30) are
properly closed.
Install the gas hoses with the pressure
reducers and the hose rupture protec-
tion devices (29) on the bottles.
A
Note:
The gas connections always have left-handed threads!
m
Make sure the gas pipe system has no leaks.
Gasflas.tif
29
30