Maintenance - Every 10 hours
2018-02-19
4812325557EN
79
Check the alternator belt tension
Use the pressure or Burroughs type gauge to check the belt
tension.
The new belt tension shall be 200 lb (890 N).
The old belt tension shall be 80
– 160 lb (360 – 710 N).
NOTE:
The belt is considered used after 10 or more minutes of
use.
NOTE:
This procedure is not applied in belt automatic
tensioners.
If the used belt tension is under the minimum
value, tighten it to the maximum allowed value
for used belts.
Drain the fuel filter
To drain the fuel filter, follow the instructions below:
1. Unscrew the drain plug (1), in the bottom of the filter.
2. With the hand-operated secondary pump (2), make sure all
the sediments were removed. For further information, refer
to the Engine Manual instructions.
3. When only clean fuel is coming out of the filter, close the
drain plug.
TAKE CARE OF THE ENVIRONMENT: All the
used oil shall be properly stored for
subsequent disposal. Do not dispose of oil on
the ground, sewage system or other place
which can harm the environment.
Fig. - Alternator belt tension
1
2
Fig.
– Fuel tank
1. Drain plug
2. Hand-operated pump