5
CC 222/222C - CC 232/232C - CC 322 M222EN5
Opening pressure MPa CC 222/322
CC 232
Drive system
42,0
42,0
Supply system
2,0
2,0
Vibration system
35,0
35,0
Control systems
20,0
20,0
Brake release
1,5
1,5
TECHNICAL SPECIFICATIONS (contd.)
Tightening torque
M
STRENGTH CLASS
thread
8.8
10.9
12.9
M6
8,4 (6.2)
12 (8.9)
14,6 (10.8)
M8
21 (15.5)
28 (20.7)
34 (21.1)
M10
40 (15.5)
56 (41.3)
68 (25.1)
M12
70 (51.6)
98 (72.3)
117 (86.3)
M16
169 (124.7)
240 (177)
290 (213.9)
M20
330 (243.4)
470 (346.7)
560 (413.1)
M24
570 (420.4)
800 (590.1)
960 (708.1)
M30
1130 (833.5) 1580 (1165.4) 1900 (1401.4)
M36
1960 (1445.7) 2800 (2065.3)
–
Tightening torque in Nm (lbf.ft) for oiled, bright
galvanized bolts tightened with a torque wrench.
Hydraulic system
Bolt size:
M24 (P/N 90 37 92)
Strength class:
10,9
Tightening torque:
800 Nm (Dacromet treated)
ROPS
Measured with vibration switched ON and on a
foam-rubber mat, standard roller
Vibration on the operator’s seat is 0,4 m/s
2
Vibration on the floor of the operator’s station is 0,2 m/s
2
The limit value is 0,5 m/s
2
Vibration - Operator’s station
(ISO 2631)
Always make sure the ROPS bolts are dry
before you torque-tighten them.
Noise level - Operator’s station
(ISO 6394)
Noise levels with vibration switched OFF (dBA)
Measured on hard surface, standard roller
Operator’s station, (with cab)
LpA: 74 dB(A)
Operator’s station, (without cab)
LpA: 84 dB(A)
Seven meters from the machine
LpA: 73 dB(A)
CAUTION