Installation, Operation and Service Manual
LKP Series 4 Channel OEM
© 2019 DynAmp, LLC
Page 4
041593O
2.5 ELECTRICAL
Four outputs are provided by the system:
a. A current output of 1 Adc per 5 kA of bus current, at TB1-30 and TB1-29. Maximum
allowable voltage drop across the terminals is 15 Vdc at the maximum current output of the
bus.
b. A standard voltage output at terminals TB1-32 & TB1-31. The voltage is 100mV/kA for models
LKP-6 & LKP-12; and 10mV/kA for models LKP-15 & LKP-30.
c. An additional voltage at TB1-36 & TB1-35, when an optional shunt is installed.
A normally closed relay contact for accuracy diagnostics output at TB1-37 & TB1-38. This
feature is only available when the accuracy diagnostics option is ordered.