5

th  

bit

 

6

th  

bit

 

7

th  

bit

 

8

th  

bit

   

5

th  

bit

 

6

th  

bit

 

7

th  

bit

 

8

th  

bit

 

ON

 

ON

 

ON

 

 

 

 

 

 

ON

 

 

 

 

OFF

   

OFF

 

OFF

 

OFF

   

 

 

 

2)   There is no PCM equipment occupying Sa bit connecting in series in the E1 link 
3)   The local and remote equipment should not all be set to the transparent mode. 

 

 

As shown in the above figure, if the above conditioned is fulfilled, the related clock 
mode and bandwidth could be set. If the connection of E1 is correct, the local LOOP 
indicator  is  Flashing,  which  means  that  the  remote  E1  interface  loop-back  is 
successful.  When  the  Router  at  the  local  site  is  checking  the  interface,  the 
loop-back status could be shown. 

 

 



 

Switch for function selection SW6

SW6 switch definition: 
 

 

1

st  

bit

 

2

nd  

bit

 

3

rd  

bit

 

4

th  

bit

 

5

th  

bit

 

6

th  

bit

 

7

th  

bit

 

8

th  

bit

 

Definition

 

Fault 

pass 
through

Reserved

 

Reserved Reserved

Selection of   the type of E1interface 

impedance

 

ON

 

Enable

   

 

 

OFF

 

Disable

 

Normal

 

Normal

 

Normal

 

E1 interface type-user could set 

according to practical application. The 

default is 75

BNC.

 

1.   1

st  

bit: Selecting switch for fault pass through (default OFF)

 

1

st  

bit

 

Fault pass through

 

ON

 

Enable

 

OFF

 

Disable

 

 

When the fault pass through function is enabled, the E1 sending and receiving side alarm 
is transmitted to DCD and CTS signal of the V.35 interface. When the fault pass through 
function is disabled, the DCD and CTS signal of the V.35 interface is always effective. 
If there is local alarm on the Converter, it means that there is fault at the E1 receiving side, 
therefore the DCD signal at the V.35 interface will be closed, and there is reflection at the 
DTE equipment. 
If there is remote alarm on the Converter, it means that there is fault at the E1 sending 
side, therefore the CTS signal at the V.35 interface will be closed, and there is reflection at 
the DTE equipment. 
The DSR signal of this equipment is effective after power on. 

 

 

2.   2

nd  

3

rd  

and 4

th  

bit: Reserved switch (default OFF)

 

These  converters  are  reserved  configuration  switches  for  test.  When  the 
equipment is working, they should all be in the OFF status. 

3. 5

th   

6

th   

7

th   

and  8

th   

bit:  selecting  switch  for  the  type  of  E1  interface

 

impedance. (Default ON ON ON OFF)

 

75

 

BNC unbalance interface effective 

120

 

RJ-45balanced interface 

effective 

 

 

 

 

 

 

 

 

15 

Содержание RC 903-V35FE1

Страница 1: ...R RC C 9 90 03 3 V V3 35 5F FE E1 1 V V 3 35 5 t to o F Fr ra ac ct ti io on na al l E E1 1 I In nt te er rf fa ac ce e C Co on nv ve er rt te er r User Manual ...

Страница 2: ... is strictly forbidden to hot swap V 35 cable when the converter and the equipment connected by V 35 cable are both power on RC903 V35FE1 is integrated equipment Move carefully and do not disassemble or mend it without the guidance of Dynamix technical engineer with the anti static procedures The equipment must be grounded Do not disassemble the equipment by yourself It may cause unrecoverable dam...

Страница 3: ...bience 6 4 User Manual 7 4 1 Front panel 7 4 2 Back panel 9 4 3 Bottom Dip Switches 10 4 4 Inside Jump pin definition 16 4 5 Basic Connection 17 5 Equipment installation and Preparation 20 5 1 Installation preparation 20 5 2 Cautions when the power is on 20 5 3 Placement 21 5 4 Test of connection 21 6 Troubleshooting 22 7 Appendix 24 Explanation of CBL V35 M34F M34M D cable 24 Explanation of CBL V...

Страница 4: ... bit rate error 5 Support E1 fractional and transparent frame modes When it is in the fractional mode the time slot can be allocated at will 6 Provide 3 clock modes Master clock Slave clock and V35 terminal clock 7 When working in pairs in the fractional mode the time slot allocation of the local equipment can automatically follow that of the remote equipment 8 Internal bit error test unit can ana...

Страница 5: ...ed one standard V35 DCE interface HDB26 male transform to ISO2953 M34 female through attached cable RC904 V35FE1 BL Module one E1 interface 120Ω balanced one standard V35 DCE interface HDB26 male transform to ISO2953 M34 female through attached cable The models in shadow of the above table are included in this manual The equipment in the above table can be used in pairs or alone 4 ...

Страница 6: ...erface bit rate is N 64Kbps N 1 31 at E1 fractional pattern V 35 interface bit rate is 2048Kbps at E1 transparent pattern 3 3 Cable type When connecting to the BNC interface it is suggested to use SYV 75 2 2 coaxial cable SYV 75 2 1 or SYV 75 1 1 could also be chosen When connecting to RJ 45 interface it is suggested to use 0 6mm 22AWG twisted pair When connecting to DTE equipment such as Router t...

Страница 7: ...3 5 Structure Standalone Dimensions 120 W 39 H 155 D mm 3 6 Ambience Operation temperature 0 45 C Operation humidity 90 25 C 6 ...

Страница 8: ...ighest Off there is no data flow of RD signal at the V 35 interface Test status Indicator TEST yellow On bit error test function is enabled In the fractional mode the local or remote loop back function is correctly set In the transparent mode the local loop back function is correctly set Flashing bit error test function is enabled In the fractional mode the local or remote loop back function is wr...

Страница 9: ...ed On Receiving code violation CV alarm Flashing Receiving code violation CV alarm only effective at fractional mode Off Local and remote signal are normal CRC red On Receiving CRC4 check error alarm Flashing Receiving CRC4 check error alarm only effective at fractional mode Off Local and remote signal are normal Attention This equipment supports CRC4 check self adaptive function When there is CRC...

Страница 10: ...cted to 0V of DC power supply 48V is connected to 48V of DC power supply V 35 interface The left figure shows V 35 interface ISO 2593 connector Our converter adopts DCE Connector Face 34 Pin Female connector which can be connected with DTE cable The definition of interface is shown below I Input O Output Pin name Input Output Pin number Chassis Ground CGND A Signal Ground GND B Receive Data A RD A...

Страница 11: ...here are 6 groups of 8 bit DIP switches The positions of the six switches are called SW1 SW2 SW3 SW4 SW5 and SW6 Every switch is like the above figure OFF is below and ON is above There is a DIP switches explanation table on the rear board as follows V35 Interface Power supply Interface Timeslot configuration switch SW1 to SW4 The means enable and means disable SW1 switch definition default OFF 1s...

Страница 12: ... OFF SW4 switch definition default OFF 1st bit 2nd bit 3rd bit 4th bit 5th bit 6th bit 7th bit 8th bit Definition TS24 TS25 TS26 TS27 TS28 TS29 TS30 TS31 ON OFF Attention If SW1 1 is in the transparent mode TS1 to TS31 switches are not effective If SW1 1 is in the fractional mode TS1 to TS31 switches are effective and cannot be all OFF At least one timeslot is enabled or else it is not fractional ...

Страница 13: ...is an internal bit error test unit in this equipment Its main function is to produce a pseudo random series in the format of 2E15 1 Std which will be sent to the E1 line User could load this series to proper data channel through configuration and then with multiple loop back function the returned series can be checked by the equipment The result will be shown on the PAT indicator on the front pane...

Страница 14: ...on which means that it has received the right test code 3 When the loop back ALOOP function at the local V 35 interface is enabled the local equipment must be working in the Master clock mode or V 35 terminal clock mode or else it will not work normally At this time the test code returns to the internal of the equipment for check before it is sent out of the E1 interface It means testing some func...

Страница 15: ...ly used to test whether the connection of V 35 cable is all right whether the Router interface has started working and whether the clock and data phase relation between Converter and Router is right or not and so on 2 Local E1 line loop back test DLOOP DTE V 35 E1Channal V 35 DTE orV 35bit error tester As shown in the above figure user can set the fractional transparent mode related clock mode and...

Страница 16: ...g switch for fault pass through default OFF 1st bit Fault pass through ON Enable OFF Disable When the fault pass through function is enabled the E1 sending and receiving side alarm is transmitted to DCD and CTS signal of the V 35 interface When the fault pass through function is disabled the DCD and CTS signal of the V 35 interface is always effective If there is local alarm on the Converter it me...

Страница 17: ... or agreement of Dynamix technical engineer Usually it is not necessary unless it is in sever environment or disturbance After opening the case you can see two groups of Jump pin JP2 and JP3 on the upper layer of the circuit board Its position order of pin and default configuration is as follow Definition of Jump pin JP2 1 PGND protection ground 2 BNC_GND BNC screened layer 3 GND working ground Th...

Страница 18: ... E1 mode in Master clock Slave clock structure Master clock Slave clock As the above figure shows when connecting Routers or other equipment with V 35 interface using point to point pattern Routers are required to work at DTE mode For the convenience of installation and preparation users can set Master Clock Mode in local converter and Slave Clock Mode in remote converter and the clock source shou...

Страница 19: ...emote converter and must configure clock frequency at V 35 interface of local DTE equipment When using Terminal clock Slave clock connection structure if DXC and MUX devices are connected in series in E1 link then DXC MUX and remote converter should be at Slave Clock Mode following E1 link clock 3 Point to point fractional E1 mode in Slave clock Slave clock structure Clock source Slave clock Slave...

Страница 20: ...ck relations bandwidth distribution and time slot usage etc If any one of them does not match the setting of the converter there will be problems in connection In this case if devices at both ends work in fractional E1 mode usually the clock relation is easily ignored It is suggested that first make sure which device the clock source is on then devices at other end should follow the clock on the E...

Страница 21: ...ut Input Input When 120Ω balanced interface connects with other devices it is required to make sure of the pin definition of other devices The pin connection method of twisted pair on both ends is shown as follow RC series converter BALANCE RJ45 E1 transmission device balanced interface TD Signal output TD Signal output RD Signal input RD Signal input Attention When connecting the twisted pair TD ...

Страница 22: ...ate loop back first check clock mode bandwidth setting of local converter and try to adjust TX CLK and RX CLK phase select switch 2 After successfully finishing the first step check if communication in the E1 link works properly If converters work in pairs and No 0 time slot is not blocked in the E1 link then remote loop back test can be processed If remote E1 port loop back test is successful the...

Страница 23: ...ng side and the E1 frame mode parameters of the opposite equipment Alarm indicator for the error of E1 receiving signal AIS LOF LOMF CV CRC Flashing Answer It means that the E1 receiving side of the remote equipment in other words the sending side of the local equipment has some problem Severe packet loss of the equipment Answer The possible reasons for severe packet loss are 1 Incorrect clock mod...

Страница 24: ...V 35 module which can be installed in the standalone extendable Multiplexer 2 RC800 30B FV35 N x 64K V 35 interface PDH fiber optic multiplexer equipped with all the functions of RC903 V35FE1 and RC800 30B single E1 PDH fiber optic multiplexer 3 This converter could also cooperate with other brand converter with similar function It could also cooperate with the E1 interface of Node 23 ...

Страница 25: ...is cable is for the clients who have the need of extending cable Please specify the length of cable when ordering The making method is as follow The other pins are not connected Requirement the material of cable is equal to or better than 80 C 30V Explanation of CBL V35 M34M M34M X D This cable is cross end connection cable for the V 35 DCE interface connection of the Converter and DDN type Node e...

Страница 26: ...oth M34 pin male interface Name of signal Pin number Pin number Name of signal TD A P R RD A TD B S T RD B RD A R P TD A RD B T S TD B RCLK A V U SCTE A RCLK B X W SCTE B SCTE A U V RCLK A SCTE B W X RCLK B SGND A A SGND GND B B GND TCLK A Y No connection Y TCLK A TCLK B AA No connection AA TCLK B DCD F F DCD DSR E E DSR CTS D D CTS RTS C C RTS DTR H H DTR The other pins are not connected Requirem...

Отзывы: