TOTALS Page
1. Category:
The type of counts that are displayed. Use the UP/DOWN to cycle
between the different Categories:
[TIME]
(Number of seconds spent dosing),
[COUNT]
(Number of times each outlet has dosed), and
[AVERAGE]
(Average duration of each dose; TIME divided by COUNT)
2a. Period time:
(Resettable)
The counts for each outlet/inlet since the IVM was last re-set.
2b. Total time:
(Non-Resettable)
The counts for each outlet/inlet for the life of the valve (monitor).
3a. Outlets:
Each outlet has its own resettable Period and Total counters.
3b. Inlets:
TIME and COUNTS for the valve inlet (top of the stem in the RDSA) are
also logged. This can be used for cross-checking correct operation. If the
system and valve are functioning properly, the inlet count should be close
to the sum of the outlet counts. Some variation will occur due to the time
for the flow to reach the valve and cause the RDSA to “seat”. Inlet time
should also be very similar to the time logged by the pump dosing the
valve (eg. Compare to the elapsed time meter - ETM data for the pump).
Also note, the IVM “inlet sensor” logs time when the IVM is powered up
but not installed on the valve.
Oct 2020 IVM6000-LP
TM
Quick Start Guide Page 11
PER
1:000021001
2:000021221
3:000020834
4:000020999
5:000021101
6:000080428
I:000132000
003344343
003445621
003323212
003212100
003121010
000101916
017210000
TOTAL
TIME
Keypad functions
UP/DOWN: Cycle between categories
PAGE:
Go to next screen
3b. Inlet
1.Category
2a. Period time column
2b. Total time column
3a. Outlets