VALVE STATUS Page
1. Outlet on-time
percentages:
The percentage of time that each outlet has been on (dosed) during
the sampling period. If the system is functioning ideally, these
should be almost equal.
For a 6 outlet valve (shown above), the percent distribution to each
outlet should be approximately 16% to 17% if the valve is dosing all
zones evenly. For a 4 outlet valve, the percent distribution should
be approximately 25%.
2. Alarm status:
Displays the alarm condition. OK means everything is fine, WARN
means that there is a warning condition, ERR means that there is
an alarm condition and the alarm relay output has been activated.
See Table 1: IVM6000 Alarm Status Reference Table for a list of the
various alarms, warnings and events.
3. Current outlet
status:
Shows a graphical representation of the valve and activity. The
center circle represents the inlet, while each numbered circle
represents an outlet. A filled/dark circle represents activity, while a
clear circle represents inactivity. In this example of normal
operation, both outlet #3 and the inlet are active.
Page 10 IVM6000-LP
TM
Quick Start Guide Oct 2020
Keypad functions
PAGE: Go to next screen
ALARM: Toggle the alarm contacts on/off.
1.Outlet # and percentages
2. Alarm status
3. Current outlet status
(outlet 3 is active in this
example)