No. 60027, Issue 4. January 1998
3 General Description
4
3.1
General Features
The SLM has the following general features:
!
Servo output capable of supplying 5 A continuous and 30 A peak to a 24 V
servo actuator.
!
Fully DXBUS compatible.
!
Two identical DXBUS sockets for Daisy Chain connection to the DX System.
!
Powered by a 24 V wheelchair battery via the DXBUS connection, or directly
from the battery for high current applications.
!
Fully programmable for optimum driving performance.
!
Lighting outputs are TÜV approved when fitted with approved regulated power
supply (SLM-TÜV).
!
Electromagnetically compatible:
- not susceptible to high levels of RFI
- emitting low levels of RFI
- protected against high levels of ESD.
!
Compact case for mounting under the wheelchair seat.
3.2
Safety and Protection Features
The SLM has the following safety and protection features:
!
Motor current limit and current limit timeout set to prevent overheating of
motors.
!
Thermal protection to reduce current limit.
!
Short circuit protection of all inputs and outputs except between motor and
battery negative while driving.
!
Open circuit motor detection when not driving.
!
Driving is inhibited if steering clutch is disengaged.
!
Over voltage, under voltage and reverse battery protected.