4 Specifications
5
4 Specifications
4.1 Electrical Specifications
T
amb
= -25 to 50
E
C, V
BAT
= 24.0 V unless otherwise specified.
Symbol Parameter
Conditions
Min Nom
Max Units
V
BAT
Battery Voltage
18.0 24.0
32.0 V
P
Q
Quiescent Power
All outputs off
1.5
2.0 W
P
SB
Standby Power
12VLM Off
24
mW
Turn Indicator Output (each output)
I
TIO
Continuous output Output On
2.3
2.5 A
current
V
TIO
Output voltage
Output On, V
TIO
= 1.5A, 13.1
13.5
13.9 V
T
amb
= 20
E
C
Side Light (Head/Tail Light) Output
I
SLO
Continuous output Output On
2.3
2.5
A
current
V
SLO
Output voltage
Output On, V
TIO
= 1.5A, 13.1
13.5
14.9 V
T
amb
= 20
E
C
13.5V Regulated Power Supply
V
REG
Output voltage
Voltage In 18-32V
12.9 13.6
14.3 V
I
TOT
Total Lighting
Max total lighting
8.0
A
output current
load
(see note below)
I
MAX
Max output
Supply shorted to ground 7.5
9.0
11.0 A
current
Note :
The total lighting output current corresponds to the side lights and hazard
flashing. The supply will current limit at 9A (nominal) to blow fuses. It is not
intended to be used at this level for any extended period of time.