Installing a 12VLM requires the following steps:

1. Mounting and securing the 12VLM

 Refer Section 5.2

2. Connecting the 12VLM to the rest of the DX system

 Refer Section 5.3

3. Connecting the 12VLM to the Lighting

Refer Section 5.4

3. Programming the 12VLM

Refer Section 7.0

5.2

Mounting

5.2.1 Environmental Protection

The 12VLM must be mounted in a position which offers the maximum protection
from water and mechanical abuse. The 12VLM provides protection up to  IP54
when mounted in the recommended orientation as shown below, but other
orientations can be used if environmental conditions are sheltered.

Содержание DX 12V

Страница 1: ... control system 2 Due to continuous product improvement Dynamic reserves the right to update this Manual This Manual supersedes all previous issues which must not continue to be used 3 Any attempt to gain access to or in any way abuse the electronic components and associated assemblies that make up the wheelchair control system renders the Manufacturer s Warranty void and the Manufacturer free fro...

Страница 2: ... 5 1 General 8 5 2 Mounting 8 5 2 1 Environmental Protection 8 5 2 2 Securing the 12VLM 9 5 3 12VLM Connection with the DX System 11 5 3 1 21 Way Connector Pin Definitions 11 5 3 2 Wires and Terminations 11 5 3 3 DXBUS Connections 12 5 3 4 12VLM Connection to the Battery 13 5 3 5 Battery Type 13 5 4 12VLM Connection to the Lighting 14 6 Operation 15 6 1 12VLM Activation 15 7 Programming 16 7 1 PCD...

Страница 3: ... Connection Faults 21 8 2 2 12VLM Programming Related Faults 21 8 3 Connected Device Faults 22 9 Electromagnetic Compatibility EMC 23 10 Maintenance 24 11 Safety and Misuse Warnings 25 11 1 Disclaimer 26 12 Warranty 27 13 Sales and Service Information 28 14 Appendix A Abbreviations 29 15 Appendix B 12VLM Accessory Parts List 30 ...

Страница 4: ...mote with lighting control switches as a minimum system See diagram below The lighting consists of side lights and turn indicators The indicators are flashed together to provide a hazard warning The lights are accessed by the DX Remote The 12VLM has two standard DXBUS connectors for connection to the DX System In a TÜV system instructions for connecting the DXBUS and lighting must be followed This...

Страница 5: ...X compatible Module has its own Installation Manual which describes the installation requirements of that particular Module This Manual describes the installation of the 12VLM only and must be read in conjunction with the DX Power Module PM Installation Manual DX Hand Held Programmer HHP Manual Dynamic Wizard Installation Sheet Online Help Installation Manuals for all other DX Modules to be used i...

Страница 6: ...ote The turn indicators are flashed at 75 flashes per minute and both left and right indicator outputs are activated when the hazard lights are selected The hazard lights can only be deactivated by re selecting the hazard button on the DX Remote If a DX Combined Lighting Actuator Module CLAM is installed in the DX System the 12VLM takes over its lighting functions All lighting outputs are fully pr...

Страница 7: ...ed against high levels of ESD Compact rugged enclosure providing protection against water and dust up to IP54 Easy slide mounting bracket 3 2 Safety and Protection Features The 12VLM has the following safety and protection features Lighting outputs and 13 5V supply protected against external short circuits to either battery terminal or other outputs Reverse battery protected Detection of a single ...

Страница 8: ... 1 5A 13 1 13 5 13 9 V Tamb 20EC Side Light Head Tail Light Output ISLO Continuous output Output On 2 3 2 5 A current VSLO Output voltage Output On VTIO 1 5A 13 1 13 5 14 9 V Tamb 20EC 13 5V Regulated Power Supply VREG Output voltage Voltage In 18 32V 12 9 13 6 14 3 V ITOT Total Lighting Max total lighting 8 0 A output current load see note below IMAX Max output Supply shorted to ground 7 5 9 0 11...

Страница 9: ... CT 30 34 64 30 5 125 85 M5 thread STATUS M ODULE 12V IGHTING L 4 2 Mechanical Specifications Size 125 85 30 mm Weight 0 5 kg including the mounting plate Mounting Chassis and tube mounting with optional brackets Case material Pressure die cast aluminium powder coat finish Case Protection Tamper proof IP54 if mounted as per mounting instructions see section 5 2 ...

Страница 10: ...ssions CISPR 11 class B ESD ISO 7176 part 21 Durability ISO7176 14 If only one DXBUS outlet is used on the 12VLM a DXBUS plug outlet cover must be inserted on the unused outlet Water and Dust IP54 when mounted as per section 5 2 mounting instructions Vibration Specification CTL Test Standard 4 G s for 2 hours per paragraph 4 3 6 Electric Wheelchairs Allows a wheelchair to comply to ISO7176 The DX ...

Страница 11: ...tion 5 3 3 Connecting the 12VLM to the Lighting Refer Section 5 4 3 Programming the 12VLM Refer Section 7 0 5 2 Mounting 5 2 1 Environmental Protection The 12VLM must be mounted in a position which offers the maximum protection from water and mechanical abuse The 12VLM provides protection up to IP54 when mounted in the recommended orientation as shown below but other orientations can be used if en...

Страница 12: ... A GME 60526 Plastite Screws x2 Tubes 18 21 mmØ GSC 0175 Tubes 21 24 mmØ GSC 0180 Square Mounting Bracket 18 24 mm DX Aux Mod Lock GME 60525 supplied with LM 5 2 2 Securing the 12VLM The 12VLM is supplied fitted with a DX Aux Mod Mounting Bracket This allows the 12VLM to be chassis mounted tube mounted or mounted to another DX Auxiliary Module as follows Round or Square Tube Mounting Chassis Mount...

Страница 13: ...011 Issue 8 October 1998 5 Installation 10 M5 x 12 CSK x2 GSC 0052 DX Aux Mod Mounting Bracket on LM DX Aux Mod Lock GME 60525 supplied with LM Another DX Auxiliary Module Mounting on other Auxiliary Modules ...

Страница 14: ...lights 5 3 1 21 Way Connector Pin Definition 5 3 2 Wires and Terminations To build a matching connector to fit to the 21 way connector the following parts are available DX 21W Plug Housing Part Order Number GCN 0796 DX 21W Boot Part Order Number GCN 0795 DX Positronic Contact FC114N2 Lge Part Order Number GCN 0793 DX Positronic Contact FC116N2 Med Part Order Number GCN 0797 DX Positronic Contact F...

Страница 15: ...s the DXBUS for communications only and the two power conductors are unused The DXBUS cables are available in the following standard lengths DXBUS CABLE Straight 0 12 M Part Order Number GSM 630012 DXBUS CABLE Straight 0 3 M Part Order Number GSM 63003 DXBUS CABLE Straight 0 5 M Part Order Number GSM 63005 DXBUS CABLE Straight 1 0 M Part Order Number GSM 63010 DXBUS CABLE Straight 1 5 M Part Order...

Страница 16: ... Amp hours The maximum average discharge rate must not exceed half the rated capacity in Amp hours High continuous discharge rates dramatically reduces the available battery capacity For example at a discharge rate equal to the rated capacity the available capacity it 50 60 At a discharge rate of half the rated capacity the available capacity is 70 80 A wheelchair that draws maximum average batter...

Страница 17: ...ing to operate The Side Light Output is active pull down when the light is turned on with one side of the bulb connected to 13 5V This output is used to power head and tail lights Multiple bulbs can be connected to the output in parallel as shown in the following diagram The Left and Right Indicator Outputs are also active pull down when the light is turned on with one side of the bulb connected t...

Страница 18: ...efore very dependent on what remote it is used with and the programmable options that are set up for it For TÜV compliance the DX Remote must support the Hazard Lockout feature That is while hazard lights are flashing the turn indicators can not be used Most DX Remotes support this feature Contact a Dynamic Sales and Service Centre for further information Please consult the User Manual for the DX ...

Страница 19: ...ibed in the Wizard Installation Sheet 2 Use the keyboard or mouse to select the File Open menu option 3 Select the SuperChair Deluxe program from the file dialog box 4 Select the Edit Module Parameters menu option 5 Select Lighting Parameters 7 Scroll through the list of parameters and adjust as necessary 8 Press Enter to accept the changes or ESC to exit without saving Select the File Save menu o...

Страница 20: ...et to No in a LM system Sidelights Enable State yes no Default yes If set to Yes sidelights are enabled If set to No there will be no response to a DX Remote sidelight head or tail button being pressed other than a beep from some varieties of DX Remotes Lighting buttons can be disabled if the DX Remote used in a system has lighting buttons that do not have the corresponding lights attached Indicat...

Страница 21: ...ion 7 1 To Enable Disable a 12VLM proceed as follows 1 Plug HHP into the Programmer Socket on the DX Remote and turn the DX System on The initial screen appears for two seconds DX HHP Vx x 2 Then the main menu screen appears MAIN MENU View or edit Program 1 NEXT YES 3 Press NEXT until the Technician Mode screen appears MAIN MENU Technician Mode disabled Enable NEXT RIGHT 4 Press NEXT and a screen ...

Страница 22: ...chnician Mode Disabled 6 Press NEXT until the screen reads MAIN MENU View or edit Remote Module Tech Only NEXT YES Press YES 7 Press NEXT until the Lighting screen is displayed LIGHTING enabled Disable EXIT NEXT YES Press YES to toggle the lighting to enabled 8 Press EXIT The HHP returns to the main menu ì The parameter setting is now saved with the 12VLM enabled Unplug the HHP and turn off the DX...

Страница 23: ... nature of the fault There are only two DX faults that are 12VLM related Flash Code 1 DX Module Fault Flash Code 2 DX Accessory Fault Refer to the DX Remote Installation Manual for a full list of Flash Codes Faults that affect the safety of the chair will cause the chair to stop while less critical ones will be indicated but allow the chair to continue driving Some faults will automatically clear ...

Страница 24: ...ection to it is faulty 2 Check the reliability of the DXBUS plug connection to the remainder of the DX system 3 Check the battery connection and fuse to the 12VLM 4 Replace either the 12VLM or the DXBUS cable where necessary 8 2 2 12VLM Programming Related Faults The 12VLM may not run at all or operate in an unexpected way if the programmable parameters are not set up correctly Using the PCD exami...

Страница 25: ... Flash Code 2 on the DX Remote s System Status LED Possible causes are Light Bulb Open Circuit If a bulb is open circuit attempted activation will cause a non latching DX Accessory Fault Light Bulb Output Short Detection of a light bulb short circuit may cause a DX to B or 13 5V Accessory fault when activation is attempted Latching faults should not occur ...

Страница 26: ...mising Emissions Motors Motor brushes generate electromagnetic emissions It may be necessary to fit capacitors between the brush holders and motor case Ensure the leads are kept as short as possible A suitable capacitor is 4n7 250V Ceramic Wiring Keep wire lengths as short as practical for a tidy layout Minimise any wire loops particularly loops of single wires as opposed to wire pairs Endeavour t...

Страница 27: ...for 5 seconds and turn the system back on If the fault does not clear contact a Dynamic Service Centre 3 All DX System components should be kept free of dust dirt and liquids If necessary wipe with a cloth dampened with warm water or alcohol Do not use solvents 4 Where any doubt exists consult your nearest Service Centre or Agent 5 There are no user serviceable parts in any DX System component do ...

Страница 28: ... that the wheelchair performs to the specifications entered in the programming procedure If the wheelchair does not perform to specifications turn the wheelchair off immediately and re program Repeat procedure until the wheelchair performs to specifications Do not operate your DX System if it behaves erratically or shows abnormal response heating smoke or arcing Turn the system off at once and con...

Страница 29: ...r and Control Systems for Electric Wheelchairs ISO7176 21 Requirements and Test Methods for Electromagnetic Compatibility of Electric Powered Wheelchairs and Scooters However the performance of controllers fitted to wheelchairs and scooters is very dependant on the design of the wheelchair or scooter Final compliance must be obtained by the vehicle manufacturer for their particular vehicle No comp...

Страница 30: ...our Should the faulty module be no longer currently available an equivalent current module would be supplied The Warranty is subject to the provisions that the equipment Has been correctly installed Has been used solely in accordance with this manual Has been properly connected to a suitable power supply in accordance with this manual Has not been subjected to misuse or accident or been modified o...

Страница 31: ... 3 339 1283 Christchurch New Zealand Australia Electronic Mobile Service EMS Tele 24 hr Int 61 2 9887 2824 46 Berripa Close Pager Int 61 2 9963 1778 North Ryde Sydney Fax Int 61 2 9887 2114 NSW Australia 2113 North America Rosstron Inc Telephone Int 1 310 539 6293 1521 W 259th St Fax Int 1 310 539 4078 Harbor City CA 90710 USA Europe Controls Dynamic Ltd Telephone Int 44 1562 820 055 Lisle Avenue ...

Страница 32: ...ectrostatic Discharge HHP Hand Held Programmer The HHP can be used by both DX System and all DLxxUxxx Controllers IEC International Electrotechnical Committee IP54 Ingress Protection rating ISO International Standards Organisation LED Light Emitting Diode PM DX Power Module The DX Module that produces the DX System output to the motors and park brakes RFI Radio Frequency Interference TÜV A German ...

Страница 33: ...Mod Lock one supplied with 12VLM 9 GME60526 DX Aux Mod Tube Clamp A 9 GME60527 DX Aux Mod Tube Clamp B 9 GSC0170 Plastite Screw 9 GSC0175 Plastite Screw 9 GSC0180 Plastite Screw 9 GSC0052 M5 x 12 CSK Screw 9 GSM63001 DXBUS Cable straight 0 1 M 12 GSM63003 DXBUS Cable straight 0 3 M 12 GSM63005 DXBUS Cable straight 0 5 M 12 GSM63010 DXBUS Cable straight 1 0 M 12 GSM63015 DXBUS Cable straight 1 5 M ...

Отзывы: