![Dynamic Mounting Down and Out Motor Mount Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/dynamic-mounting/down-and-out-motor-mount/down-and-out-motor-mount_installation-directions-manual_2548198012.webp)
Install Video at
www.DynamicMounting.com/Install
12
Controller Lights
Flashes Green when IR remote button is pushed
Yellow, flashing slowly – (Commissioning Mode)
Controller is not connected to WiFi, comes out of the box
this way, lasts for 10 minutes after powering up or holding
the reset button.
White, flashing slowly – (No Network Mode) Controller is
Not connected to WiFi, IR will still work.
Blue, flashing slowly – Controller is connected to WiFi
Green, flashing slowly – Controller connecting to WiFi
upon powering up, if unable to connect it will keep
flashing.
Red, while moving - needs to be calibrated
Reset Button on Controller
Controller Reset Button – Small circular hole located right
next to the light. Need a paperclip to actuate.
Hold button for different lengths of time to achieve
different things.
o
1 White Flash – Delete WiFi connection and put in
Commissioning Mode
o
3 White Flashes – (Default) Clears WiFi Network and
deletes all of the positions
Controller Specs
WiFi Security – IMC170 works with Open, WPS, WEP
Personal, WEP Enterprise.
Works only with 2.4 GHz band
Connecting to WiFi
1.
Put controller in Commissioning Mode (Flashing Yellow
Light)
Cycle the Power, if that doesn’t work;
Hold reset button until it flashes white once, do NOT hold
for longer
2.
On Phone/Computer connect WiFi to network IMC170
Make sure auto-reconnect is selected, may need to
deactivate auto-reconnect for other networks while
setting up.
Dismiss unsafe connection warnings
3.
4.
Select the WiFi Network (SSID) the mount will
communicate on
5.
Type in the WiFi Networks Password
6.
DHCP, Dynamic (Enabled) or Static (Disabled) IP Address
Dynamic
IP (DHCP Enabled)
Default setting, is easier to connect to, if unsure, use this one.
7.
For Dynamic IP addresses skip Static IP section and go to
step 11
Static IP (DHCP Disabled)
Takes a little more work to setup but is steadier and some Home
Automation systems require it. If unsure about IP addresses, use
Dynamic.
8.
Type in an empty address for Static IP
9.
A Typical Netmask is already typed in
10.
Type in The Gateway Address
Typically the WiFi router’s IP Address
Connect to WiFi
11.
Press the Connect button, controller will reboot with the
new IP address, IMC170 network and 192.168.200.1 will
no longer be available.
12.
On Phone/Computer Connect to same WiFi network as
selected in step 4
Controllers Website
13.
The IP address of the controller can be input into any
browser on the same network to access the controller.
o
The Dynamic IP Address can be found with the
on a smartphone. Mount Controller will be named
Generic, Newport Media
o
Can also be found on the computer by viewing the
networks, will be named IMC170
o
Static IP address is the one you created in step 8
14.
Save the Webpage address so that it can easily be accessed
to control the TV.
Webpage Settings
This page is not needed during normal use. Click the 3 bars
button then settings
Connect – Connect to WiFi Network
Restart – Updates the positions on the website’s Motor
Tab
Calibrate – Drives the mount down to the very bottom
position to zero the controller position, can also be done by
pressing set, run, holding set until mount moves down all of
the way and the red light flashes.
Reset – Deletes all of the positions on the controller
Default – Clears WiFi Network and deletes all of the
positions
Note:
For additional information about the IP controller and how to connect to other systems go to