4
1.2 Unpacking, Bill of Materials
Using the following bill of materials, open the cartons and check off the items to see that all
material was received in good condition. Notify Dynamax no later than 10 days after receipt
if there are any discrepancies. Notify the shipper and Dynamax immediately if goods are
damaged in transit by mishandling.
If AVRD is purchased as part of a data logger system, items in the BOM would be assembled
in to the logger and ready for operation. Other wise the items in BOM will be supplied as
mentioned below.
1.2.1 Bill of materials
1. AVRD - Dual High current, High efficiency voltage regulator
2. In-line fuse holder with fuse (5 mm x 20 mm, 15A)
3. Spare male (2 ea.) and female (2 ea.) quick disconnect spade terminals
4. Mounting kit
a. Screws (6/32-1/2”) – qty 2
b. Hex nut 6/32 - qty 4
Optional:
1. 12V/ 5Ahr battery
2. 12V/ 7Ahr battery
3. AC outlet adapter 15V / 4A
4. Solar Panel, 10W (MSX10), 30W (MSX30), 60W (MSX60) as per the sensor requirement
1.3 Specifications
OUTPUT
Output voltage Range
1-10 V variable
Output current
5 A max. per channel
Output Control
15 turn precision potentiometers (~0.6
V/turn) ON/OFF switch; SHDN signal
Reference Voltage
0.8 V
No. of regulated outputs
2
No. of terminals per output
2
No. of terminal per output expandable to
6 (requires custom assembly at the factory)
Efficiency
80% (3 V to 8 V)
90% (8 V - 10 V)
INPUT
Input voltage range
10-36 VDC
Minimum input voltage
10 V