SYSTEMS WITH VOLTAGE REGULATION
Model
Regulator Included Standard Maximum Upgraded System - Add:
Flow2
Internal 1A
AVRD
Flow32-A
AVRD
AVRD
Flow32-B
AVRD
AVRD
Flow32-C
AVRD
AVRD
FLGS-TDP
(2) AVRD
-
FL32-GS8
AVRD
AVRD
FL32-GS16
(2) AVRD
-
FLDL-TDP
-
AVRD
DL2e
-
AVRD
DL3000
-
AVRD
SV1 (Delta-T Devices Kit)
-
AVRD
The specific sensor excitation voltage requirements are found in the installation manual for
that sensor. To determine the voltage for specific conditions and the type of sensor refer
to the sensor installation manual. The following table gives a quick picture of the typical
voltage requirements.
SENSOR REQUIREMENTS
Model
Type
Range
SGA2-3
Dynagage Microsensors
2-3 V
SGA5
Dynagage Microsensor
3.5-4.5 V
SGA10-SGB25
Dynagage Stem Gauges
3.5-5 V
SGB35-SGA70
Dynagage Trunk Gauges
5-7 V
SGA100
Dynagage Trunk Gauges
6-10 V
TDP-10-50
Granier Sap Velocity Sensor
2-5 V
TDP-80
Dual Sap Velocity Sensor
7.5 V
TDP-100
Triple Sap Velocity Sensor
8 V
4.0 Safety and Maintenance
PRECAUTIONS
1. The AVRD series regulators are not waterproof. The AVRD’s should be installed in
protected enclosures, NEMA 2,3 or 4 rated.
2. The regulator is internally protected from over-current. Nevertheless, do not short output
(+) leads to ground or minus leads. This can cause damage to wires, the regulator and
eventually burn up the device.
3. In addition to over-current latching AVRD is protected by an external in-line fuse 15A; 5 x
20mm (considering 5A max current on each).