IMPORTANT - PLEASE READ BEFORE PROCEEDING! 
 
The  Dynalco  model  MTH103E  is  designed  for  reliable  and  rugged  operation  on 
engines, turbines and other rotating equipment. This product has been designed and 
tested  to  meet  the  demands  required  in  many  industrial  and  hazardous  locations 
meeting  critical  CSA  standards.  The  performance  is  directly  related  to  the  quality  of 
the installation and knowledge of the user in operating and maintaining the instrument. 
To  ensure  continued  operation  to  the  design  specifications,  personnel  should  read 
this  manual  thoroughly  before  proceeding  with  installation,  operation  and 
maintenance  of  this  instrument.  If  this  product  is  used  in  a  manner  not  specified  by 
Dynalco, the protection provided by it against hazards may be impaired. 
 
 

   

WARNING

 

 

 

Failure  to  follow  proper  instructions  may  cause  any  one  of  the  following 
situations  to  occur:  Loss  of  life;  personal  injury;  property  damage;  damage  to 
this instrument; and warranty invalidation. 

 

 

For  clarification  of  instructions  in  this  manual  or  assistance  with  your 
application, contact Dynalco at (800) 368-6666 or (954) 739-4300 or send email to 

[email protected]

 

 

 

Additional manuals and CSA certificates are available at 

www.dynalco.com

  

 

 

Follow all warnings, cautions, and instructions marked on and supplied with the 
product. 

 

 

Use  only  qualified  personnel  to  install,  operate,  program  and  maintain  the 
product. 

 

 

Educate your personnel in the proper installation, operation, and maintenance of 
the product. 

 

 

Install  equipment  as specified  in  the  installation  section  of  this  manual.  Follow 
appropriate  local  and  national  codes.  Only  connect  the  product  to  power 
sources and end devices specified in this manual. 

 

 

Any  repair  is  only  to  be  performed  by  Dynalco  using  factory  documented 
components.  Tampering  or  unauthorized  substitution  of  parts  and  procedures 
can affect the performance and cause unsafe operation of your process. 

 

 

All  equipment  doors  must  be  closed  and  protective  covers  must  be  in  place 
unless qualified personnel are performing maintenance. 

 

 

Shutdown / alarms should be tested monthly for proper operation (see page 8) 

 

 

Please see pages 9 & 10 for CSA specific installation instructions. 

To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]

Содержание MTH-103E

Страница 1: ...d Ave Los Angeles CA 90058 MTH 103E Tachometer Hourmeter Trip Installation and Operation Manual Rev E P N145F 13048 c Copyright 2014 Dynalco Controls All Rights Reserved Published March 18 2014 To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 2: ...ssistance with your application contact Dynalco at 800 368 6666 or 954 739 4300 or send email to customerservice dynalco com Additional manuals and CSA certificates are available at www dynalco com Follow all warnings cautions and instructions marked on and supplied with the product Use only qualified personnel to install operate program and maintain the product Educate your personnel in the prope...

Страница 3: ...ommand Fast overspeed reaction time of 100 milli seconds Design incorporates hardware and materials creating a weatherproof unit that allows installation in poorly protected areas This is ideal for both indoor and outdoor installations Standard Society of Automotive Engineers SAE case fits engine panels with 3 3 8 inch 86 millimeter openings Unit is highly shock and vibration resistant Face plate ...

Страница 4: ...ion The MTH 103E is designed to be panel mounted The dimensions are shown below The MTH 103E includes a bracket for securing into the panel To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 5: ...re made to terminals on the back of the unit Terminal screws to be tightened to 8 inch pounds torque See pages 9 10 for complete wiring information Programming Overview To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 6: ... Press to enter or accept values Select up Select down Go back one screen Select and advance to next screen Initial configuration consists of the following steps 1 Programming the gear teeth 2 Selecting over under speed setpoints if required 3 Pre setting hourmeter if required To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 7: ...de The main configuration screen shows the following icons Gear Teeth Settings for selecting number of gear teeth Hourmeter Settings configures hourmeter count up or count down Alarm Settings for enabling low high alarms Alarm Logs for accessing alarm log info System Settings for selecting default display Configuration of Gear Teeth Settings Using the arrows on the keypad select the Gear Teeth Set...

Страница 8: ...uired for example System Settings Using the arrows on the keypad select the System Settings icon There are 2 display layouts available either Large RPM Digit or RPM Hourmeter Note that you are selecting the default layout type You will be able to change the layout during normal operation by pressing the left right arrows After setting the layout type pressing the right arrow will allow the user to...

Страница 9: ...cation on the display will blink and the digital output will trip The alarm shutdown triggers a TRIAC rated at 150 mA for switching either an annunciator input or an external relay This TRIAC is similar to the SCR used in the previous version MTH 103D in that current flow must be removed to reset the TRIAC This can be accomplished by providing a momentary contact closure across the 2 output termin...

Страница 10: ...9 To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 11: ...10 To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Отзывы: