31
Outputs:
Max. output current (relay contacts):
1A
at
24VDC
0.5A
5OVDC
Installation example:
Installation example with factory presets: see also ”Factory preset sequences” page 36 - 44
INPUTS:
All input signals must be applied longer than 200 msec. in orderto be securely recognized. Modifying this default is
possible in the menu ”Trigge@’.
Al
Release signal:
Input for re-confirmation signal, whether the unit (power amplifiers) is ready
A2
General Stop:
Input (impulse); interrupts all currently running sequences
A3
Alarm text:
Input (impulse) for playback alarm message (MOO)
A4
DIN alarm:
Input (impulse) for infinite DIN alarm (siren 1200 Hz - 500 Hz).
Bl
DIN alarm:
Key pressed for DIN alarm on, key released terminates the alarm
B2
DIN alarm text:
Key pressed starts sequence, DIN alarm, 1 sec pause, alarm text (MOO),
1 sec pause, DIN alarm, etc., key released terminates the sequence.
B3
4-tone gong:
Input (impulse) starts a 4-tone gong (G20).
B4
Pre-gong:
Input (static), key pressed starts pre-gong and enables announcement via
DMM 4650, key released terminates the sequence.
OUTPUTS:
All outputs are floating relay contacts.
Al
System on:
Switches on the electro acoustics sound reinforcement system.
A2
Alarm text running:
Signaling contact for alarm text active.
A3
Alarm signal running:
Signaling contact for alarm signal active.
A4
4-tone gong running:
Signaling contact for 4-tone @g active.
Bl
Pre-gong running:
Signaling contact for pre-gong active.
B2
Mandatory relay E:
Switches the sound reinforcement system to mandatory reception (E).
B3
Mandatory relay D:
Switches the sound reinforcement system to mandatory reception (D).
B4
Program off:
Switches current music program off.