![DynaColor QIG-510 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/dynacolor/qig-510-series/qig-510-series_installation-manual_2547392014.webp)
Installation Guide
13
3.1.4
Camera Control Protocol Setup
Define the protocol you are going to use basing on the devices of your
surveillance system. Generally, use one protocol even the devices are
provided from different manufacturers. Please refer to the table below for all
supported protocols with their matching switch numbers and baud rate and
choose a protocol for your Speed Dome Camera.
Switch No.
Protocol
Baud Rate
00
VCL 9600
01
Pelco D
2400
02
Pelco P
4800
04
Chiper 9600
05
Philips 9600
07
DSCP 9600
08
AD422 4800
09
DM P
9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2400
14
Pelco P
9600
15
JVC 9600
21
Kalatel-485 9600
22
Kalatel-422 4800
23
Panasonic 19200
Use the 6-bit dip switch (Camera Control Protocol Switch) to set your
camera’s control protocol and its baud rate.
If select protocol: Pelco D, which is of switch no. 01 and baud rate 2400, for
instance, set the SW 6 to “ON,” with the rest to “OFF,” as shown below.
For switch configuration details, please refer to
Appendix B: Switch Settings
Index Table
in the Dome Camera’s User Manual.