CAUTION:  EQUIPMENT OVERLOAD

Keep the generator load within the generator and
receptacle nameplate rating.  Overloading may cause
damage to the generator and/or the loads .

Grounding

All units must be grounded.  Drive a 3/4 or  1" copper pipe or
rod into the ground close to the engine-generator set.  The
pipe must penetrate moist earth.  Connect an approved
ground clamp, to the pipe.  Run a no. 10 Awg wire from
clamp to the generator ground lug on the generator.  Do not
connect to a water pipe or to a ground used by a radio
system.

ENGINE CARE

If major engine service or repair is required contact an
authorized engine service center.  The manufacturer of
these engines has established an excellent worldwide
engine service organization.  Engine service is very likely
available from a nearby authorized dealer or distributor.
Check the yellow pages of your local telephone directory
under “Engines-Gasoline” for the closest engine repair
center or ask the dealer from whom you purchased the
power plant.

1.  Change the oil after the first five hours of operation

and every 50 hours thereafter under normal
operating conditions.  Change engine oil every 25
hours of operation if the engine is operated under
heavy load, or in high ambient temperatures.

a.  Remove oil drain plug at base of the engine

and drain the oil with the engine warm.

b.  Replace oil drain plug.
c.  Remove oil filler plug and refill with new oil.

Refer to the table in the engine manual for the
proper grade of oil based on your operating
temperature.

d.  Replace filler plug.

2. Checking the Oil Level: The oil level must always be

checked before the engine is started.  Take care to remove
any dirt or debris from around the oil fill plug before
removing.  Be sure the oil level is maintained. Fill to the
“FULL” mark on the dipstick.

3. Cartridge Air Cleaner - Remove and clean cartridge

yearly or after every 25 hours, whichever occurs first. Service
more often if necessary.  Clean by tapping gently on flat
surface.  If very dirty, replace the cartridge using only original
equipment parts available at any engine service center.

Do not use petroleum solvents, such as kerosene, to

attempt to clean the cartridge.  They may cause
deterioration of the cartridge.  DO NOT OIL CARTRIDGE,
DO NOT USE PRESSURIZED AIR TO CLEAN OR DRY
CARTRIDGE.

4. Dual Element Air Cleaner - Clean and re-oil foam

pre-cleaner at three month intervals or every 25 hours,
whichever occurs first. Service more often under dusty
conditions.

a. Loosen screws and remove cover and air cleaner

assembly from base.

b. Remove foam pre-cleaner by sliding it off the

paper  cartridge.

c. Wash foam pre-cleaner in liquid detergent and

water

d. Wrap foam pre-cleaner in cloth and squeeze dry.
e. Saturate foam pre-cleaner in engine oil. Squeeze

to remove excess oil.

f. Install foam pre-cleaner over paper cartridge.

Reassemble cover and screw down tight.

Replace the cartridge included with Dual Element Air
Cleaner yearly or every 100 hours.  Service more often  if
necessary.

5. Spark Plug - Clean and reset gap at .030" every 100

hours of operation.  Do not blast clean spark plug.  Clean by
scraping or wire brushing and washing with a commercial
solvent.  Poor spark will occur if terminal does not fit firmly
on spark plug.  If this happens reform the terminal to fit
firmly on spark plug tip.

GENERATOR CARE

Proper care and maintenance of the generator is necessary
to insure a long trouble free life.

1. Exercising The Generator - The generator should be

operated every three to four weeks.  It should be
operated for a period of time sufficient to warm the
unit up and to dry out any moisture that has
accumulated in the windings.  If left, this moisture can
cause corrosion in the winding. Frequent operation of
the engine generator set will also insure that the set
is operating properly should it be needed in an
emergency.

2. Generator Maintenance - Any major generator service

including the installation or replacement of parts should be
performed only by a qualified electrical service technician.
USE ONLY FACTORY APPROVED REPAIR PARTS.

a. Bearing - The bearing used in these

generators is a heavy duty double sealed ball
bearing. They require no maintenance or
lubrication.

b. Receptacles - Quality receptacles have been

utilized.  If a receptacle should become cracked or
otherwise damaged, replace it.  Using damaged or
cracked receptacles can be both dangerous to the
operator and destructive to the equipment.

CLEANING

Remove dirt and debris with a cloth or brush.  DO NOT use
high pressure spray to clean either the engine or the
generator.  This high pressure spray could contaminate the
fuel system and the generator components.

1. Keep the air inlet screen on both the engine and

generator free of any dirt or debris to insure proper cooling.
At least yearly remove the blower housing on the engine
and clean the chaff and dirt out of the engine cooling fins
and flywheel.  Clean more often if necessary. Failure to
keep these areas clean may cause overheating and
permanent damage to the unit.

2. Periodically clean muffler area to remove all grass,

dirt and combustible debris to prevent a fire.

3. On engine mufflers equipped with spark arresters, the

spark arrester must be removed every 50 hours for cleaning
and inspection.  Replace if damaged.

Содержание CSADL6000I/E

Страница 1: ...INSTALLATION OPERATION and MAINTENANCE INSTRUCTIONS CSADL6000I E CSADL6000IE E ...

Страница 2: ...CTIONS Initial Starting 4 Starting 4 Starting Hints 4 Stopping And Storage 4 Operating Speed 5 Connecting The Loads 5 OPERATOR CARE AND MAINTENANCE Engine Care 6 Generator Care 6 Cleaning 6 Troubleshooting Things To Check BEFORE You Call For Service 7 Complete Unit Parts List 8 Receptacle Panel Parts List 9 Wiring Diagram 10 WARRANTY 10 Read and understand all instructions in the manual before sta...

Страница 3: ...RE HAZARD Gasoline and other fuels always present a hazard of possible explosion and or fire a Do not refuel when the engine is running or hot Allow the engine to cool at least two minutes before refueling b Keep fuel containers out of reach of children c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers ...

Страница 4: ... The generator winding might also be damaged CAUTION EQUIPMENT DAMAGE RUNNING THE GENERATOR SET UNDER THESE CONDITIONS MAY RESULT IN DAMAGING THE GENERATOR STATOR AS WELL AS THE MOTOR WINDING Because the heavy surge of current required for starting motors is required for only an instant the generator will not be damaged if it can bring the motor up to speed in a few seconds of time If difficulty i...

Страница 5: ... is especially true if an unexpected shutdown would cause a safety hazard or serious inconvenience for the operator UNPACKING CAUTION EQUIPMENT DAMAGE THIS UNIT HAS BEEN SHIPPED WITHOUT OIL Failure to maintain the engine oil at the proper level will result in serious engine damage When you unpack your new ENGINE GENERATOR be sure to remove all the information sheets and manuals from the carton 1 T...

Страница 6: ... run position CAUTION EQUIPMENT DAMAGE Never permit the choke to remain on after the engine has run for a short time It is not necessary to choke the engine when it is warm Avoid over choking STARTING HINTS 1 Cold weather a Use the proper oil for the temperature expected b Use fresh winter grade fuel Winter grade gasoline is blended to improve starting Do not use summer gasoline 2 Hot weather a Us...

Страница 7: ...r sets are inherently self regulating based on engine speed The engine governor will automatically adjust itself to the load No harm to the generator will result if it is operated with no load connected Proper utilization of the receptacles located on the control panel is necessary to prevent damage to either the receptacles or the generator The generator is a limited source of electrical power th...

Страница 8: ...sembly from base b Remove foam pre cleaner by sliding it off the paper cartridge c Wash foam pre cleaner in liquid detergent and water d Wrap foam pre cleaner in cloth and squeeze dry e Saturate foam pre cleaner in engine oil Squeeze to remove excess oil f Install foam pre cleaner over paper cartridge Reassemble cover and screw down tight Replace the cartridge included with Dual Element Air Cleane...

Страница 9: ...itor Defective stator Defective rotor field Circuit Breaker Over Loaded Trips Defective receptacle Defective circuit breaker Too small long of drop cord Voltage too high Engine speed is too high Generator Overloaded overheating Insufficient ventilation No output voltage Short in load disconnect Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective ...

Страница 10: ...nts 4 16249 000 4 Locknut 5 16 18 5 16250 000 1 Flange Nut 3 8 16 6 464 000 1 Cap Screw 3 8 16 X 75 7 16335 007 1 Generator Support 8 15676 005 1 Battery Tray 1 NI 15767 005 1 Negative Battery Cable 1 NI 15767 016 1 Positive Battery Cable 1 NI 15807 000 1 Battery Holddown Kit 1 9 15617 003 1 End Cover Assembly 10 63073 031 1 Cradle Assembly 11 58684 011 1 Edge Trim ...

Страница 11: ...6 006 1 Complete Generator Assembly 14 15632 007 1 Engine B S Intek 1 210317 0191 B1 14 15632 008 1 Engine B S Intek 2 210312 0190 B1 15 468 000 2 Cap Screw 5 16 18 X 1 5 16 480 000 2 Lockwarsher 5 16 17 466 000 2 Cap Screw 1 4 20 X 75 18 512 000 2 1 4 Flat Washer 19 16133 000 2 Leather Washer 20 81018 008 1 Clamp 21 98771 000 1 Fuel Valve 22 62999 001 2 Fuel Line Clamp 23 40078 000 28 1 4 Fuel Li...

Страница 12: ...rior to placing the unit in service The user shall assume all risks and liability in connection with determining the suitability of the unit for its particular use Neither the manufacturer nor the seller shall be liable for any injury loss or damage arising out of improper use or operation of this unit In no event is WINCO liable for incidental or consequential damages Some states do not allow lim...

Отзывы: