background image

Propane/LP

Supply Valve

Propane/LP

Tank

Regulator

Fuel Gas

Fitting

Hose to 

Heater

PROPANE CONSTRUCTION HEATER

INSTALLATION TO THE PROPANE GAS TANK

IMPORTANT: 

You must use a propane/LP gas supply cylinder that is compatible with the connection device 

provided with the hose and regulator.

REFILLING THE PROPANE GAS TANK

ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.

• Turn heater gas valve knob and gas tank valve to OFF position.

• Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS. Turn POL fitting

  CLOCKWISE to loosen. Protect POL fitting when disconnected from tank.

• Have tank filled by your local Propane gas supplier.

• Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE.

• With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks 

  with soap solution.

 

       

WARNING

Purging and filling of LP gas tanks must be performed by personnel who

         has been thoroughly trained in accepted LP gas industry procedures. Failure to follow 
these instructions may result in explosion, fire, severe personal injury, or death.

1. Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob 
    fully clockwise (       ). Ensure that the cylinder is fully upright for vapor withdrawl. (see size/capacity, page 7).
2. Connect hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.    

  

3. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s).
    3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on tank. Tighten  
    firmly using a wrench. Some models have a hand wheel that can be used to tighten the fitting. This hand 
    wheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT: 
    Position regulator so that hose leaving the regulator is in a horizontal position.
    3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on tank. Tighten    
    firmly using your hand (DO NOT USE A WRENCH). IMPORTANT: Position regulator so that the regulator 
    vent is pointing down toward the floor and the arrow on the regulator is visible.
4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, excess flow
    device in regulator may stop gas flow. If this happens, close propane/LP supply valve, wait one minute 
    (or until you hear a click) and open again slowly.
5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints.
    Bubbles forming show a leak that must be corrected.
6. Close propane / LP supply valve before attempting to repair connection.

Connector Inlet

Hose to Regulator

Hose Fitting

 FIGURE 1 

 FIGURE 2 

 FIGURE 3 

6          

7

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Содержание LPFA125WH

Страница 1: ...S ETCETERA CONTACT THE MANUFACTURER CONSUMER Retain this manual for future reference Printed in China IMLPFWH HDW USER S MANUAL AND OPERATING INSTRUCTIONS PROPANE CONSTRUCTION HEATER LPFA40WH 40 000 B...

Страница 2: ...PROPOSITION 65 Fuels used in gas or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects or other reproduc...

Страница 3: ...RTANT READ THIS USER S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO OPERATE OR SERVICE THIS HEATER IMPROPER USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE EXPLOSION AND CARBON MONO...

Страница 4: ...and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively Use only the regulator hose assembly provided with the heater Inspect the regulator hose asse...

Страница 5: ...Minutes Contents All Models Unit Manual Hose and Regulator Assembly FA100 FA150 Series Includes 2 Cord Wrap Attachments 4 Screws ST3 5x10 Tools required for assembly All Models Adjustable Wrench FA100...

Страница 6: ...the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure regulator and hose assembly supplied with this heater must be used without alteration The hose assembly shal...

Страница 7: ...thdrawl see size capacity page 7 2 Connect hose to heater inlet Tighten firmly using a wrench You must use the regulator supplied with heater 3 Connect fuel gas fitting hose regulator assembly to prop...

Страница 8: ...ach use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall...

Страница 9: ...erforming any Mainte nance functions Unplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free 3 Have unit checked by a qualified technician at...

Страница 10: ...voltage is correct electrical connec4on is made check power cord and extension cord for 2 Fan blade contacts inside of heater housing 2 Be sure that housing is not damaged Make sure there are no obstr...

Страница 11: ...WIRING DIAGRAMS PROPANE CONSTRUCTION HEATER 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 12: ...WIRING DIAGRAMS 100K 125K 150K Models only 100K 125K 150KS lo modelos 100K 125K 150K Les mod les Seulement PROPANE CONSTRUCTION HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 12...

Страница 13: ...MODELS LPFA40WH LPFA60WH REPLACEMENT PARTS LIST PROPANE CONSTRUCTION HEATER 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 14: ...FA40 GS22A FA60 18 PRESSURE SWITCH 1 N A N A 19 VALVE BRACKET 1 2304624 2304624 20 BASE ASSEMBLY BLACK 1 2304923 2304923 21 POWER CORD ASSEMBLY 1 2201368 2101670 22 GAS CONNECTOR INLET 1 2304831 2304...

Страница 15: ...MODELS LPFA125WH LPFA150WH PROPANE CONSTRUCTION HEATER PROPANE CONSTRUCTION HEATER ILLUSTRATED PARTS BREAKDOWN 15 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 16: ...6 19 VALVE BRACKET 1 2304624 2304624 20 BASE ASSEMBLY BLACK 1 2304924 2304924 21 POWER CORD ASSEMBLY 1 2101673 2101673 22 GAS CONNECTOR INLET 1 2304831 2304831 23 CAPACITOR 1 2301390 2301390 24 BASE L...

Страница 17: ...ntative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND...

Страница 18: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280...

Отзывы: