![Dyna-Glo EG7500DGP Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/dyna-glo/eg7500dgp/eg7500dgp_installation-and-maintenance-instructions-manual_2546473003.webp)
3
ITEM
PAGE #
SPECIFICATIONS ........................................................................... 3
SAFETY INFORMATION ................................................................. 3
LOCATING HEATER ....................................................................... 4
PRE-INSTALLATION ....................................................................... 5
INSTALLATION ............................................................................... 6
OPERATING INSTRUCTIONS ........................................................ 10
MAINTENANCE .............................................................................. 12
REPLACEMENT PARTS ................................................................. 12
TROUBLESHOOTING .................................................................... 13
1. Use only copper wires rated for at least 60ºC.
2. Heater air flow must be directed parallel to or away from adjacent wall.
3. Observe all wall, floor and ceiling clearance requirements.
4. All wiring must be done according to national and local electrical codes. The
heater must be grounded as a precaution against possible electrical shock.
Heater circuit must be protected with proper fuses.
5. The mounting structure and the anchoring hardware must be capable of
supporting the weight of the heater and the mounting bracket (if used).
TABLE OF CONTENTS
SPECIFICATIONS
SAFETY INFORMATION
THIS HEATER REQUIRES HARDWIRE INSTALLATION (NO PLUG). THE INSTALLATION OF THIS
PRODUCT MUST BE CARRIED OUT BY A CERTIFIED ELECTRICIAN AND IN ACCORDANCE WITH
ALL LOCAL AND NATIONAL ELECTRICAL CODES.
NOTE: COMPATIBLE WITH A 240V LINE VOLTAGE DOUBLE POLE WALL THERMOSTAT. MUST BE
INSTALLED BY A CERTIFIED ELECTRICIAN.
READ AND UNDERSTAND ALL INSTALLATION & OPERATION INSTRUCTIONS PRIOR TO
OPERATING THIS UNIT. OBSERVE ALL SAFETY INSTRUCTIONS.
WARNING
Rating
Switch Setting
Volts
Phase
Hz
AMPS
BTU/hour
7500W
II
240
1
60
31.25
22590
5000W
I
240
1
60
20.9
17060
Rating
Switch Setting
Volts
Phase
Hz
AMPS
BTU/hour
5600W
II
208
1
60
26.9
19107
3700W
I
208
1
60
17.9
12625