![Dyna-Glo EG7500DGP Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/dyna-glo/eg7500dgp/eg7500dgp_installation-and-maintenance-instructions-manual_2546473013.webp)
TROUBLESHOOTING
PROBLEM
ROOT CAUSE
CORRECTIVE ACTION
Unit is not
heating.
The overheat protection has
activated.
Inspect the garage heater and
check that the air inlets and outlets
are not blocked as this may cause
overheating. Switch off the circuit
breaker to the garage heater for 30
minutes and allow it to cool down.
Turn the power back on and operate.
The breaker has tripped
Reset the breaker at the fuse panel
and restart the heater
The room temperature has
already reached the set
thermostat temperature
Adjust the temperature setting to
make sure the thermostat
setting temperature is higher than
current room temperature.
Garage heater
emits a
burning smell
During production dust and/
or oil debris gathered on
heating coils.
Make sure the room is well
ventilated. Allow the garage heater to
run until the smell is dissipated.
Check and make sure there
is no combustible material
within 0.9 meters (3 feet) of
the garage heater.
Remove the combustible material
around the garage heater.
This heater must be
mounted at least 8 feet
off the floor, for specific
clearances, please check
the "LOCATING HEATER"
section in the instruction
manual
Relocate the garage heater so there
is enough space between the heater
and adjacent wall and floor.
13