Dyna-Glo DELUX LPFA43DGD Скачать руководство пользователя страница 5

4

PROPANE CONSTRUCTION HEATER

Accidents are always tragic especially because so many of them could have been prevented with little care 

and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.

•  Children should be carefully supervised, when they are in the area.

•  Always maintain proper clearance from combustible materials. Minimum clearance from combustibles: 

Side - 24” (61 cm); Top - 36” (92 cm); Front - 72” (183 cm). Floor - combustible. Not for use on finished floors.

•  Heater must be placed on level and stable surface.

•  Never place anything including clothes or other flammable items on the heater.

•  The appliance area shall be kept clear and free from combustible materials, gasoline and other flammable 

vapours and liquids.

•  Do not modify or operate a heater which has been modified.

•  Adequate clearance for accessibility and for combustion & ventilation air supply must be maintained at all times 

when the heater is operating.

•  Service and repair should be done by a qualified service person. The heater should be inspected before each 

use and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not 

service while hot or operating.

•  Never connect heater to an unregulated gas supply.

•  The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only, do not 

convert heater to any other gas. Installation must conform to local codes or, in the absence of local codes, with 

the standard for the Storage and Handling of Liquefied Petroleum Gases  ANSI/NFPA 58 and the Natural Gas 

and Propane Installation Code CSA B149.1

•  The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure, 

respectively. Use only the regulator & hose assembly provided with the heater. Inspect the regulator/hose 

assembly prior to each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with 

regulator/hose assembly listed on the parts list prior to using this heater.

•  Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame to 

check for gas leaks.

•  The electrical connection & grounding must comply with National Electrical Code. ANSI/NFPA 70 or in Canada 

CSA C22.1, Canadian Electrical Code, Part 1. Use only a properly grounded three (3) prong receptacle.

•  Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed.

•  This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be 

located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.

•  The propane cylinder supply system must be arranged to provide for vapour withdrawal from the operating 

cylinder.

•  This heater is not to be used with external thermostats, timers or other devices that control or alter electrical 

supply to the heater. 

•  Heater must be placed on a flat stable surface. Do not position the heater at any other angle than the intended 

design position. Certain models can change the up and down tilt angle by loosening the “height control screw” 

and moving the “height controller”, then retightening the “height control screw”.

•  This heater is not designed to thaw ground surfaces.

•  Installation of this Appliance at altitudes above 2000 ft. (610 m) shall be in accordance with local codes, or 

in the absence of local codes the, National Fuel Gas Code, ANSI Z223.1 / NFPA 54, or National Standard of 

Canada, Natural Gas and Propane Installation Code, CSA B149.1.

PRODUCT FEATURES

 

 

• Portable & Stable   

 

 

• 100% Safety Shutoff System

 

 

• Wind Resistant & Rain Protected  

• Continuous Adjustable Input Rating

 

 

• Piezo Electric Spark Ignition

GENERAL SAFETY INSTRUCTION

IMPORTANT SAFETY INSTRUCTION

 

     

WARNING

Motor and fan must be running before lighting, during operation and at shutdown, 

      in order to prevent a flame-out condition which could result in personal injury or property damage.

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Содержание DELUX LPFA43DGD

Страница 1: ...RDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSI...

Страница 2: ...ES OR UNKNOWN CHEMICALS WARNING This product and the fuels used to operate this product liquid propane and the products of combustion of such fuels can expose you to chemicals including benzene which...

Страница 3: ...Gas and Propane Installation Code CAN B149 1 as appropriate Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about...

Страница 4: ...0 16 4mm Size LxWxH 16 2 x8 3 x11 9 41 2x21 1x30 2 cm USA 8 Hr Time weighted average OSHA 29 CFR 1926 55 App A CO 50 ppm CO2 5000 ppm NO2 USA Ceiling Limit Short Term Exposure Limit 15 minutes CO CO2...

Страница 5: ...ve abrasion or wear or hose is cut replace with regulator hose assembly listed on the parts list prior to using this heater Gas supply connections should be checked using a 50 50 solution of liquid di...

Страница 6: ...damage promptly inform dealer distributor where you purchased heater Assembly Components and Instructions for Steel Base Units Regulator and Hose Connection See figure on right Connect the hose tight...

Страница 7: ...Gas Cylinder Valve Outlets and Inlet Connections A safety relief valve having direct communications with the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure regu...

Страница 8: ...t the valve on the cylinder is fully closed by turning the knob fully clockwise Ensure that the cylinder is fully upright for vapor withdrawl see size capacity page 6 2 Connect hose to heater inlet Ti...

Страница 9: ...e construction Side 24 61 cm Top 36 92 cm Front 72 183 cm Floor combustible must be maintained at all times The hose assembly should be visually inspected prior to each use of the heater If it is evid...

Страница 10: ...nplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free so that ventilation and combustion air is not obstructed 3 Have unit checked by a quali...

Страница 11: ...Damaged Control Valve 2 Replace Control Valve 3 Dust or debris build up inside of heater 3 Clean inside of heater PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1 Control dial is o and unit is 1 This heater...

Страница 12: ...NEGRO GREEN VERT VERDE BLACK NOIR NEGRO BLACK NOIR NEGRO WHITE BLANC BLANCO WHITE BLANC BLANCO WIRING DIAGRAM IF ANY ORIGINAL WIRING SUPPLIED WITH THIS HEATER MUST BE REPLACED IT MUST BE TYPE AWG 105...

Страница 13: ...MODEL FA43 Series 12 PROPANE CONSTRUCTION HEATER REPLACEMENT PARTS LIST NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 14: ...1 2304885 13 GAS TUBING ASSEMBLY 1 FA43 CR 11 14 WIRE 1 2201371 15 CONTROL KNOB BLACK 1 2101451 CONTROL KNOB ORANGE 1 2305466 16 VALVE 1 GS22 FA43 17 BASE ASSEMBLY BLACK 1 FA43 CR 07 BASE ASSEMBLY GR...

Страница 15: ...tative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND...

Страница 16: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 A...

Отзывы: