Dyna-Glo DELUX LPFA43DGD Скачать руководство пользователя страница 3

2

PROPANE CONSTRUCTION HEATER

TABLE OF CONTENTS

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

The heater is designed and approved for use as a construction heater under ANSI Z83.7 CSA 2.14. It is hard 

to anticipate every use which may be made of this heater. 

CHECK WITH YOUR LOCAL FIRE SAFETY 

AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.

DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS

This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended 

use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the 

products of combustion generated by the heater are forced through the heater and released into the area being 

heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount 

of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon 

monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning 

or death.
For either indoor or outdoor use. Adequate ventilation shall be provided in accordance with OSHA 29 CFR 

1926.154, Safety Requirements for Temporary and Portable Space Heating Devices and Equipment ANSI 

A10.10, ANSI 223.1 / NFPA 54, Liquified Petroleum Gas Code, NFPA 58 or the National Gas and Propane 

Installation Code, CAN B149.1 as appropriate.

Other standards govern the use of fuel gases and heat producing products in specific applications.

Your local authority can advise you about these.

IMPORTANT:

 READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING 

TO OPERATE OR SERVICE THIS HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE 

SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION AND CARBON MONOXIDE POISONING.

WARNING

NOT FOR USE WITH DUCT WORK.

•  Do not use this heater for heating human living quarters.

•  Use of direct-fired heaters in the construction environment can result in exposure to  levels of CO, CO

2

, and 

NO

2

 considered to be hazardous to health and potentially life threatening.

•  Do not use in unventilated areas

•  Know the signs of CO and CO

2

 poisoning

 ▫ Headaches, stinging eyes

 ▫ Dizziness, disorientation

 ▫ Difficulty breathing, feels of being suffocated

•  Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain acceptable 

air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety 

Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction 

Industry or the Natural Gas and Propane Installation Codes CSA B149.1

 ▫ Periodically monitor levels of CO, CO

2

 and NO

2

 existing at the construction site – at the minimum at the 

start of the shift and after 4 hours.

 ▫ Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor 

air quality

     WARNING

Air Quality Hazard

Содержание DELUX LPFA43DGD

Страница 1: ...RDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSI...

Страница 2: ...ES OR UNKNOWN CHEMICALS WARNING This product and the fuels used to operate this product liquid propane and the products of combustion of such fuels can expose you to chemicals including benzene which...

Страница 3: ...Gas and Propane Installation Code CAN B149 1 as appropriate Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about...

Страница 4: ...0 16 4mm Size LxWxH 16 2 x8 3 x11 9 41 2x21 1x30 2 cm USA 8 Hr Time weighted average OSHA 29 CFR 1926 55 App A CO 50 ppm CO2 5000 ppm NO2 USA Ceiling Limit Short Term Exposure Limit 15 minutes CO CO2...

Страница 5: ...ve abrasion or wear or hose is cut replace with regulator hose assembly listed on the parts list prior to using this heater Gas supply connections should be checked using a 50 50 solution of liquid di...

Страница 6: ...damage promptly inform dealer distributor where you purchased heater Assembly Components and Instructions for Steel Base Units Regulator and Hose Connection See figure on right Connect the hose tight...

Страница 7: ...Gas Cylinder Valve Outlets and Inlet Connections A safety relief valve having direct communications with the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure regu...

Страница 8: ...t the valve on the cylinder is fully closed by turning the knob fully clockwise Ensure that the cylinder is fully upright for vapor withdrawl see size capacity page 6 2 Connect hose to heater inlet Ti...

Страница 9: ...e construction Side 24 61 cm Top 36 92 cm Front 72 183 cm Floor combustible must be maintained at all times The hose assembly should be visually inspected prior to each use of the heater If it is evid...

Страница 10: ...nplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free so that ventilation and combustion air is not obstructed 3 Have unit checked by a quali...

Страница 11: ...Damaged Control Valve 2 Replace Control Valve 3 Dust or debris build up inside of heater 3 Clean inside of heater PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1 Control dial is o and unit is 1 This heater...

Страница 12: ...NEGRO GREEN VERT VERDE BLACK NOIR NEGRO BLACK NOIR NEGRO WHITE BLANC BLANCO WHITE BLANC BLANCO WIRING DIAGRAM IF ANY ORIGINAL WIRING SUPPLIED WITH THIS HEATER MUST BE REPLACED IT MUST BE TYPE AWG 105...

Страница 13: ...MODEL FA43 Series 12 PROPANE CONSTRUCTION HEATER REPLACEMENT PARTS LIST NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 14: ...1 2304885 13 GAS TUBING ASSEMBLY 1 FA43 CR 11 14 WIRE 1 2201371 15 CONTROL KNOB BLACK 1 2101451 CONTROL KNOB ORANGE 1 2305466 16 VALVE 1 GS22 FA43 17 BASE ASSEMBLY BLACK 1 FA43 CR 07 BASE ASSEMBLY GR...

Страница 15: ...tative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND...

Страница 16: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 A...

Отзывы: