U S E R G U I D E
|
U V C S S I D E CU R E C O N V E Y O R
9
Lamp Installation and System Interconnect
NOTE: Refer to the Dymax UVCS Lamp manuals for detailed Irradiator and Power Supply information.
1.
Uncrate and assemble the Conveyor’s optional Mounting Cart if applicable.
2.
Uncrate the Conveyor and remove the protective coverings. Place the Conveyor on a convenient work surface or on
the Mounting Cart if purchased.
3.
Unpack the 5000-EC UVCS Lamp System(s). Each Lamp System includes a Power Supply, Reflector Assembly,
400-Watt Bulb, Amp Connector Cord, and Power Cord (Figure 3).
Figure 3.
5000-EC UVCS Lamp System
4.
Install the Bulb into the Reflector Housing (Figure 4) ensuring that the bulb is properly seated.
5.
Attach the Connector Cord to the back of each Reflector (Figure 5).
Figure 4.
Bulb Installed in Reflector Housing
Figure 5.
Lamp Reflector Housing
6.
Install the Lamp/Reflector Housing Assemblies into the Conveyor’s Upper Lamp Support Housing. Up to four
Lamp/Reflector Housing Assemblies may be installed in the Upper Lamp Support Housing. Adapter Plates are
provided with the Conveyor for each possible arrangement.
7.
When the Lamps are installed, adjust the position of the Support Housing and tighten the four Securing Knobs
(Figure 6).