BlueWave® MX-Series Multichannel Controller User Guide
User Mode (DB):
The current user mode (Admin, Production, or PLC) will be displayed on the gray button at the
top of the screen between the information and setting buttons. Pressing this button switches between
Administration, Production and PLC modes. A password will be required to enter administrator mode.
In Production Mode the production screen layout is identical to the administrator screen with the exception it
does not have trigger (TR1-4) buttons. The configuration settings reflect the administrator settings and cannot be
altered. User operational controls are limited to Volume and Brightness (see Settings screen). Program(s) names
will be displayed along with the emitter type but the ability to save and load program(s) will be disabled. The
default password is 1234.
Settings (B):
Loads the settings screen where the volume, language, screen brightness, and other user
settings can be adjusted.
Triggers (DB):
“TR1
-
TR4”
–
(Admin Screen Only) Displays the current state of
the 4 input triggers (Green - Active (Asserted); Yellow - Inactive (Deasserted)).
NOTE:
During a cure cycle pressing these will stop any LED emitter operation.
Emitter Type Display/ Wavelength (1-4):
Each emitter will have a horizontal
banner which will display the emitter number, emitter type, and emitter
wavelength.
Mode (1-4) (DB):
This button, located in the first column under the channel
number, displays the current mode of operation for each channel (timed or
manual) that is attached to an emitter.
Timed Mode (B):
Pressing this button will put this emitter into manual
mode and clear the emitter time.
Manual Mode (B):
Pressing this button will put this emitter into timed
mode and set the emitter time to the current displayed time.