Introduction 

The enclosed ACCU-

CAL™ 50 UV Radiometer was developed and 

manufactured by the Dymax team, driven by a desire to best serve 
your needs. Before shipping, your ACCU-

CAL™ 50 Radiometer was 

calibrated and tested against standard UV light sources to ensure 
accurate performance. 

The operation of this radiometer in conjunction with a UV light-
curing system will maximize safety and user-friendly performance 
and provide optimum yield of your technological process. 

Therefore, we encourage you to read, understand, and follow all 
safety and operating instructions and recommendations compiled in 
this and other related manuals prior to setting up and operating this 
instrument and any associated UV light-curing systems. 

If you encounter a problem or have any questions, please contact 
our Technical or Customer Support Departments at 860-482-1010. 
Trained Dymax professionals are standing by to serve you.  

Par conséquent, nous vous encouragez a lire, comprend, et suivre 

tout sécurité et instructions d’opération et conseillations rédiger 

dans cette et autre manuels etablir un lien avant de mettre en place 
et de faire marcher cette nouveau système de lampe de tache ou 
cettes composants individuel.  

Si vous rencontrez un problème, avait n’importe de questions, ou si 

vous voudrez de nous aider avec tes suggestions ou conseillations, 

s’il vous plait contacte notre depar

tements technique ou service 

client à 860-482-1010. Dymax formé professionals attendre a vous 
servir.  

Safety 

General Safety 

WARNING! 

This symbol alerts you to the possibility of 

serious injury or death if you do not follow the instructions.  

CAUTION!

  Always wear protective goggles or face shield 

when working near the front of any unit which emits UV light!  
The rear of some units also emit stray UV light.  

WARNING!

  Always observe safety requirements!  

PRÉ-CAUTION!

 

Toujours faisez de l’usage des lunettes de 

protection ou protéger de visage marche près du devant 

d’élément!

 

PRÉ-CAUTION!

 Risque de décharge électrique quand le 

couvert est enlever! 

 

 

Содержание ACCU-CAL

Страница 1: ...ACCU CAL 50 Radiometer User Guide ...

Страница 2: ...ction and increase throughput System designs enable stand alone configuration or integration into your existing assembly line Please note that most dispensing and curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its application and use is strictly limited to that contained in the Dymax standa...

Страница 3: ...nts Introduction 3 Safety 4 General Safety 4 Safety 5 Product Overview 5 Unpacking 6 Parts List Spot Configuration 6 Parts List Flood Configuration 6 Operation 7 Maintenance 8 Spare Parts and Accessories 8 Specifications 8 Warranty 9 Index 10 ...

Страница 4: ...nding by to serve you Par conséquent nous vous encouragez a lire comprend et suivre tout sécurité et instructions d opération et conseillations rédiger dans cette et autre manuels etablir un lien avant de mettre en place et de faire marcher cette nouveau système de lampe de tache ou cettes composants individuel Si vous rencontrez un problème avait n importe de questions ou si vous voudrez de nous ...

Страница 5: ...te gants opague vais protéger les mains Sicherheitshinweise Dieses Gerät wurde so entwickelt dass es nur vollständig alle Komponenten korrekt miteinander verbunden in Übereinstimmung mit relevanten Instruktionen betrieben wird Bei der Entwicklung wurde weiterhin großen Wert auf die Benutzersicherheit und minimale UV Belastung gelegt Sicherheitshinweise Tragen Sie immer die mitgelieferten Sicherhei...

Страница 6: ... can be shipped to you immediately Check that the parts included in your order match those listed below If parts are missing contact your local Dymax representative or Dymax Customer Support to resolve the problem Figure 1 Spot Radiometer PN39560 Parts List Spot Configuration ACCU CAL 50 Radiometer ACCU CAL 50 Radiometer User Guide 3 mm 5 mm 8 mm Adapters Lightguide Simulator PN 38408 Figure 2 Flo...

Страница 7: ...amp Lightguide by inserting the Lightguide into the Lightguide Adapter until it bottoms out Tighten the set screw when the Lightguide is installed 5 Press and release the On Off Key on the Face Plate to turn the Radiometer on and off 6 Press and release the Light Source Key to select the light source being measured The different light source options are Flood Lamp For use when measuring UV intensi...

Страница 8: ...ohol To increase battery life turn unit power off after use The unit will not automatically power off Spare Parts and Accessories Item Part Number Adapter Kit Flood to Spot Model includes parts listed below 39554 Lightguide Simulator 38408 8 mm Lightguide Adapter 39558 5 mm Lightguide Adapter 39557 3 mm Lightguide Adapter 39556 Specifications Property Specification Power Two AA size batteries Disp...

Страница 9: ... may void your warranty benefits The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment IMPORTANT NOTE DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES EXPRESSED OR IMPLIED DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT WITHOUT WRITTEN AUTHORIZATION FROM DYMAX...

Страница 10: ...UIDE ACCU CAL 50 RADIOMETER Index Accessories 8 Battery Replacement 8 Maintenance 8 Operation 7 Parts List 6 Product Description 5 Safety 4 General Safety 4 Spare Parts 8 Specifications 8 Unpacking 6 Warranty 9 ...

Страница 11: ...USER GUIDE ACCU CAL 50 RADIOMETER 11 ...

Страница 12: ...hat contained in Dymax Europe GmbH s General Terms and Conditions of Sale published on our website Dymax Europe GmbH does not assume any responsibility for test or performance results obtained by users It is the user s responsibility to determine the suitability for the product application and purposes and the suitability for use in the user s intended manufacturing apparatus and methods The user ...

Отзывы: