TM-051 PN 35903 EC Series Models 38105, 38100, 38110
Rev 04/16/08
14
NOTE:
IF THE LAMP DOES NOT IGNITE, REFER TO THE TROUBLESHOOTING SECTION OF THIS MANUAL.
LAMP BASE REPLACEMENT KIT
Installation Instructions:
1.
Turn off the power.
2.
Remove the power cord and connector cord from the unit.
3.
Remove the lamp/reflector assembly from the mounting stand and place it on a clean, flat surface with the
lamp facing up.
4.
Remove the lamp (refer to Lamp Replacement Procedure.)
5.
Remove the lamp/reflector assembly from the housing by removing the four screws, two on each side, from
the reflector.
6.
Remove the two screws, from the side of the unit, holding the ignitor in place (located inside a blue fireproof
sleeve) and remove from the sleeve.
7.
Loosen the screws and remove the wires from the ignitor at locations marked
N
and
La.
a. The black Teflon wire at location
N
will have to be clipped from the lamp base wire and re-
stripped.
8.
Remove both lamp bases and install the new lamp bases from the Lamp Base Replacement Kit.
9.
Take one of the lamp bases and crimp on a supplied terminal (P/N 35202), this wire will be installed in the
La
location on the ignitor.
10.
The remaining lamp base wire will be joined with the black Teflon wire using the supplied terminal (P/N
35218). This wire will be installed in the
N
location on the ignitor.
11.
Place the ignitor back into the blue fireproof sleeve and fasten to the side of the housing using the two
screws that had been removed in Step #6.
12.
Place the reflector back into the housing and fasten with the four remaining screws.
13.
Place the lamp back into the unit.
FUSE REPLACEMENT PROCEDURE
The EC Series 400 Watt power supply utilizes two line input fuses. These fuses are external and are located in the power
cord receptacle at the rear of the power supply housing. The fuses are 6.25 Amp, slow blow fuses.
WARNING
:
ELECTRICAL SHOCK HAZARD. EXERCISE EXTREME CARE WHEN REPLACING FUSES. MAKE SURE
ONLY QUALIFIED PERSONNEL PERFORM FUSE REPLACEMENT AND THAT ALL POWER SWITCHES ARE "OFF"
AND THE POWER CORD IS UNPLUGGED.
Replacing External Fuses:
1. Turn the power supply power switch "OFF."
2. Unplug the power cord from the electrical source.
3. Unplug the power cord from the receptacle at the rear of the power supply housing.
4. Place a small, flat blade screwdriver into the notch at the top of the plug recess and pull the fuse cover
downwards approximately 70 degrees. The fuse retainer is exposed and may be removed by pulling it
straight out.
5. Slide out the blown fuses and replace with new 6.25 Amp, slow blow fuses.