helpline manual
21
Turbine head brush bar not operating
The brush bar will stop rotating if it becomes obstructed. The brush bar will operate immediately, once the obstruction is cleared.
Press the release catch and remove
the turbine head. Ask the customer
to check the suction on the end of the
wand handle. If weak go to section 1
on p.18, if strong continue with these
checks.
Turn machine OFF and remove turbine
head. Check inlet plunger for dust/
debris. Check inlet seal for damage.
Undo both soleplate fasteners, release
the locking tab. Lift and remove the
soleplate.
Pull the brush bars out from the
turbine head. Using scissors, carefully
cut away any hair or threads from the
brush bar.
Check the turbine duct for blockages.
Check the metal spindles are rotating
freely.
Position the brush bars back into the
turbine ensuring the arrows on the
brush bars are aligned with the arrow
on the shaft.
Refit the soleplate and secure locking
tab.
Check that the soleplate is fitted flush
against the housing with no visible
gap.
1
5
6
4
9
8
7
Ask the customer to plug machine in
and test that brush bar is spinning and
the plunger is working. If not working
send new turbine head.
2
3
Plunger
Inlet seal