background image

D3000 Series User Manual 

 

Understanding the system 

Before using the system for the first time, please read the first few sections of this manual as 
well as the glossary at the back, to make sure that you are happy with all the terminology 
used. 

Within this manual, keys which need to be pressed are shown thus [OK].  Messages shown 
on the display are shown in quote marks “like this”. 

The main control panel (the brains behind the system) is housed in a plain metal box hidden 
away from danger.  All system operations are performed using the “Remote keypad” as 
shown below: 

 

 

D3000

 

Series

 

 

User

 

Manual

 

 

D3000

USER

EN/09F/v2

                                                                          ‐ 

3

 

                      

 

 

 

 

 

The main parts of the keypad are used as follows: 

Display: 

This screen is continuously updated, informing you of what is 
happening on the system. 

Set indicators: 

These red indicators are ON if the appropriate group(s) are set.  See 
Note on page 4. 

Ready indicators: 

These green indicators are ON when the appropriate group(s) are 
ready to be set.  If the indicator is OFF when you want to set the 
group(s), it means that one or more detectors are “active” i.e. a 
movement detector needs more time before it automatically resets, or 
a door needs to be closed.  See Note on page 4. 

[

OK

] Key 

[

esc

] Key 

[

flip

] Key 

Set 
Indicator 

Ready 
Indicator 

Quick Set 
Keys  

Numeric 
Keyboard 

Proximity Reader 
(D3202 and D3212) 

Power 
Indicator 

Up and Down 
Arrow Keys 

Loudspeaker 

[

menu

] Key 

Display 

Microphone (D3201 
and D3202) 

Содержание D3000 Series

Страница 1: ...t your Installer explains how the system works and the level of access each user has If you have any queries on the configuration or the operation of this Intruder Alarm System contact your Alarm Company on the following telephone number Alarm Company _____________________________________________ Telephone _____________________________________________ NOTE This manual covers 3 products D3001 D3021...

Страница 2: ...Advanced operations 8 Set or unset groups 8 Omit 24Hr zones 8 Tests 8 Test bell 8 Test strobe 8 Walk test 8 Test RKP LEDs 8 Test RKP sound 8 Test panel sound 9 View log 9 View full log 9 View alarm log 9 View user log 9 Change own code 9 Add delete users 9 Access control 9 Smoke reset 10 Omit zones 10 Arm only 10 Reset system 10 Set date and time 11 Remote access 11 Intercom 11 Helpline 11 Allow e...

Страница 3: ...USER EN 09F v2 3 The main parts of the keypad are used as follows Display This screen is continuously updated informing you of what is happening on the system Set indicators These red indicators are ON if the appropriate group s are set See Note on page 4 Ready indicators These green indicators are ON when the appropriate group s are ready to be set If the indicator is OFF when you want to set the...

Страница 4: ...indicator will flash if the mains is off or if there is a problem with the internal battery When this indicator is flashing the display will show details of the problems Microphone Used for the Intercom and the Helpline features These features are only available if a D3201 or D3202 keypad is used Proximity reader This feature is useful if users find it difficult to remember codes when setting and ...

Страница 5: ...s to the system the following information is required User number A two digit reference number used internally to identify which user is using the system User name A text name to identify each user User code The code that is used to confirm that the person at the keypad is an authorised user User functions These define whether an individual user has access to specific functions within the user s m...

Страница 6: ... enter the building via the correct entry route to avoid setting off the alarm The intermittent tone indicates that the system is in entry mode Go straight to the keypad and enter your user code followed by the OK key or place the tag against the keypad to unset all of the system Alternatively enter your user code followed by a Quick Set key A B C or D to unset specific group s The red indicators ...

Страница 7: ... about to change the group to unset or set Press OK to continue The display will now show the zone reference for the first zone that can be omitted Move up and down through all the omitable zones using the and keys pressing the 0 key to omit it or the 1 key to activate it Press OK to start the setting mode If a detector is active at this point the system will return to the unset condition Simply s...

Страница 8: ... this option there are further options as defined below Press the and keys to move between these options then press OK to select the required test Pressing the and keys will cycle around the options i e pressing the key after the last option will then show the first option again Test bell Press OK to select The display will read Bell ON and the outside sirens or bells will begin Press OK to end th...

Страница 9: ...E you are not able to see what the code is Enter your new user code followed by OK to overwrite the old code Add delete users Before entering this option ensure that you have a record of all the users on the system To edit user details press OK when this option is displayed Use the and keys to display the user number to be edited Press OK The user code for that user can then be entered new user or...

Страница 10: ...e desired access The user can be given access to autogroups These are the groups which the user will set when entering their code followed by the OK key or by placing their tag against the keypad Any combination of groups within those allocated above can be selected The first screen shows the autogroups within groups 1 to 10 groups 1 to 4 on D3021 or D3022 To allocate autogroups to groups 11 to 20...

Страница 11: ...remote location usually your Alarm Company Three options exist namely Call downloader Answer call and Start remote servicing You will be instructed by your Alarm Company when and how to use these options Intercom Press OK to contact another keypad on the system If there are more than 2 keypads you will be asked which one you want to contact Enter the keypad number and press OK NOTE when using the ...

Страница 12: ...eys enter text Multiple presses of each of the keys enter text as defined below Press Displayed 1 1 2 a b c 2 A B C 3 d e f 3 D E F 4 g h i 4 G H I 5 j k l 5 J K L 6 m n o 6 M N O 7 p q r s 7 P Q R S 8 t u v 8 T U V 9 w x y z 9 W X Y Z 0 space 0 The cursor will automatically move right one second after the last key press Alternatively the cursor can be moved right manually with the key or left wit...

Страница 13: ...d KP Sounder ON Test Panel Sound Panel Sounder ON View log View Full Alarm User Log Start Date End Date Change own code Change Own Code Add Delete users Select User Access Code Operator Name Attributes Operator Groups Groups 1 10 and 11 20 Autoset Groups Groups 1 10 and 11 20 Menu Access Set date and time dd mm yyyy hh mm Remote access Call Downloader Answer Call Start Remote Servicing Allow engin...

Страница 14: ... each time an alarm is generated After an alarm the system must be reset before it can be set again also see customer reset Entry mode When the system is set opening the relevant door will start the entry mode You will then be given enough time to walk to the keypad and enter your user code to unset the system without generating an alarm It is very important however that you go straight to the key...

Страница 15: ... When an alarm condition is generated it is common to trigger flashing lights outside the building These lights are referred to as strobes Unset When the system is unset the building is not protected and it is safe to walk around without triggering the alarm Walk test This feature provides the user with a facility to periodically test that all detectors on the system are working correctly D3000 Se...

Страница 16: ...D3000 Series User Manual D3000 USER EN 09F v2 16 NOTES ...

Отзывы: