background image

D1555_D1558 installation manual 29042022 V5 

 

 

 

12V Power Output 

Terminal blocks are provided to connect to the system.  The output is floating and can be referenced to 
earth if required.  The output is controlled by the ON/OFF input (see below).  
  
The output is electronically short circuit and overload protected and suitable for switching highly 
inductive loads.  The short circuit protection is intelligent, and power will be restored when a short is 
removed when still connected to the load, requiring no further user/installer intervention.   
The output switch-on retry time is adaptive and will be extended to a maximum of 18 seconds after a long 
duration short to prevent excessive switch power dissipation. 
 
The PSU power rail is continuously monitored for over-voltage and in the event of a high voltage 
condition, the output will be automatically switched off and a fault signalled 
 

LED Indications 

The status of the PSU is displayed by three LEDs, see below for their meaning: 

KEY 

  LED on 

  LED off  

  LED blinking  

 

State 

OK LED 

GREEN 

BAT LED 
YELLOW 

FLT LED 

RED 

AC ON 

● 

○ 

○ 

AC OFF 

○ 

● 

● 

Output Off, AC ON 

☼ 

○ 

○ 

Output Off, AC Off 

○ 

☼ 

● 

Output Fault, AC ON 

● 

○ 

● 

Output Fault, AC OFF 

○ 

● 

● 

Battery Fault, AC ON 

● 

● 

● 

Low Battery Fault, AC OFF 

○ 

● 

● 

Output Off, AC ON, Battery Fault 

☼ 

☼ 

● 

Output Off, AC ON, Output Fault Pending 

☼ 

○ 

● 

Output Off, AC OFF, Output Fault Pending 

○ 

☼ 

● 

Output Off, AC OFF, Low Battery Fault 

○ 

☼ 

● 

Output On, AC ON, Over Voltage Fault 

 

○ 

● 

Output Off, AC ON, Over Voltage Fault 

☼ 

○ 

● 

 
 
 
 

Содержание D1555

Страница 1: ...r D1555 D1558 12V Switched Mode Power Supplies Ideal for Access Control Systems Dycon Power Solutions Ltd Tel 44 0 1443 471 900 Unit A Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconpower com sales dyconpower com ...

Страница 2: ...tery connection monitoring Battery deep discharge protection Inductive and capacitive load switching surge protection and snubbing Electronic overload protection with automatic reset Highly efficient power conversion better than 84 at full load Low voltage drop when in standby mode The ON OFF switched output The ON OFF switched output is designed for highly inductive loads such as access control d...

Страница 3: ...o the monitoring equipment used to report and signal equipment faults Connect the 12V power output to the system Switch on the AC supply and confirm that the AC OK LED is lit External Power Supply AC Supply The power supply has a three way terminal block for Live Earth and Neutral connections When supplied boxed earth is connected to the metal enclosure and the lid earthed with a flying push fit l...

Страница 4: ...d to a maximum of 18 seconds after a long duration short to prevent excessive switch power dissipation The PSU power rail is continuously monitored for over voltage and in the event of a high voltage condition the output will be automatically switched off and a fault signalled LED Indications The status of the PSU is displayed by three LEDs see below for their meaning KEY LED on LED off LED blinki...

Страница 5: ...ree contacts and open collector outputs If the ON OFF input is left unconnected when the jumper is not fitted the power supply will be switched on Switching examples are shown below ON OFF 0V ON OFF 0V Open Collector Normally closed contacts Jumper not fitted PSU output on when collector is low transistor on Jumper fitted PSU output on when contacts are open Battery Management The battery is conti...

Страница 6: ...size A housing 1 x 7 8Ah 235 x 170 x 85 1 35 D1555 B D1558 B Steel medium size B housing 2 x 7 8Ah 260 x 320 x 90 2 15 D1555 XB D1558 B Steel Clam shell lid XB housing 2 x 7 8Ah or 2 x 17Ah 295 x 425 x 90 2 45 D1555 XLB D1558 XLB Steel standard size XLB housing 2 x 7 8Ah or 2 x 17Ah 295 x 425 x 90 2 45 D1555 XLBD D1558 XLBD Steel extra deep XLBD housing Up to 4 x 17Ah 295 x 490 x 165 4 65 D1555 C ...

Отзывы: