D1555_D1558 installation manual 29042022 V5 

 

 

 

Overview 

The Dycon D1555 and D1558 are 5A and 8A switched mode power supplies with an opto-relay output for 
signalling the status of the unit with PCB-mounted, LED status indicators. Both units provide a nominal 12V 
when powered from a 230V AC supply with battery backup. 
 

The power supplies have the following features: 

 

-

 

ON/OFF power switching control input with pull-up, compatible with voltage-free contacts 

-

 

Jumper for selecting normally OPEN or normally CLOSED for switched output operation 

-

 

ON (OK) LED display indicating normal operation and ON/OFF switching status 

-

 

Battery LED indicating standby operation and ON/OFF output switched status 

-

 

Fault LED and separate fault opto-relay output for comprehensive fault monitoring 

-

 

Battery connection monitoring 

-

 

Battery deep discharge protection 

-

 

Inductive and capacitive load switching surge protection and snubbing 

-

 

Electronic overload protection with automatic reset 

-

 

Highly efficient power conversion 

 better than 84% at full load 

-

 

Low voltage drop when in standby mode 
 

The ON/OFF switched output

 

The ON/OFF switched output is designed for highly inductive loads such as access control door strikes and 
locks and is protected from high voltage back-EMF spikes. 
 

Battery types 

All standard VRLA (lead acid) batteries are supported. The standard battery connector for 2.1Ah & 7/8Ah 
batteries is a FASTON 4.75.  For 17Ah & 24Ah batteries please specify M5 connectors when ordering. 

 
Connection layout for both D1555 and D1558 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Scale

1:1.5mm

Description: D1555

General Tolerances:

        +-0.5mm

Projection:

Date: 25/03/2021

Material: PCB

Version No:4

LED's

Mains Connection

Live

Earth

Neutral

BAT

PROG

INV

PSU FLT

0V

ON/OFF

-/+ 12V

M3 x 6 mm panhead

recommended with

10 mm high

hex stand off

Содержание D1555

Страница 1: ...r D1555 D1558 12V Switched Mode Power Supplies Ideal for Access Control Systems Dycon Power Solutions Ltd Tel 44 0 1443 471 900 Unit A Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconpower com sales dyconpower com ...

Страница 2: ...tery connection monitoring Battery deep discharge protection Inductive and capacitive load switching surge protection and snubbing Electronic overload protection with automatic reset Highly efficient power conversion better than 84 at full load Low voltage drop when in standby mode The ON OFF switched output The ON OFF switched output is designed for highly inductive loads such as access control d...

Страница 3: ...o the monitoring equipment used to report and signal equipment faults Connect the 12V power output to the system Switch on the AC supply and confirm that the AC OK LED is lit External Power Supply AC Supply The power supply has a three way terminal block for Live Earth and Neutral connections When supplied boxed earth is connected to the metal enclosure and the lid earthed with a flying push fit l...

Страница 4: ...d to a maximum of 18 seconds after a long duration short to prevent excessive switch power dissipation The PSU power rail is continuously monitored for over voltage and in the event of a high voltage condition the output will be automatically switched off and a fault signalled LED Indications The status of the PSU is displayed by three LEDs see below for their meaning KEY LED on LED off LED blinki...

Страница 5: ...ree contacts and open collector outputs If the ON OFF input is left unconnected when the jumper is not fitted the power supply will be switched on Switching examples are shown below ON OFF 0V ON OFF 0V Open Collector Normally closed contacts Jumper not fitted PSU output on when collector is low transistor on Jumper fitted PSU output on when contacts are open Battery Management The battery is conti...

Страница 6: ...size A housing 1 x 7 8Ah 235 x 170 x 85 1 35 D1555 B D1558 B Steel medium size B housing 2 x 7 8Ah 260 x 320 x 90 2 15 D1555 XB D1558 B Steel Clam shell lid XB housing 2 x 7 8Ah or 2 x 17Ah 295 x 425 x 90 2 45 D1555 XLB D1558 XLB Steel standard size XLB housing 2 x 7 8Ah or 2 x 17Ah 295 x 425 x 90 2 45 D1555 XLBD D1558 XLBD Steel extra deep XLBD housing Up to 4 x 17Ah 295 x 490 x 165 4 65 D1555 C ...