Dyadic Systems – Mechatronics Cylinder Manual
MF
-005500-EN-60/63
9. Diagnosis of Abnormal Operation
9.1. Diagnosis by Alarm Codes
If an Alarm is detected, please investigate it using the following chart, and then remove the cause.
The controller will send an Alarm code (see following chart) through the SIO line.
Name of Alarm
Alarm
Code
Conditions Cause
Action
Bank 30 data error
B0
Occurs when bad data
was entered
Out of range data
entered
Modify data to fall within
the range
Bank 31 data error
B1
Encoder stall judge
error
B8
Occurs when power
was turned ON
Defective controller
Replace product
Defective motor
Replace product
Occurs other than
above case
Defective controller
Replace product
Encoder counter
error
B9
Occur when power
was turned ON
Defective controller
Replace product
Defective motor
Replace product
Shaft seized
See Below (Action 1)
Homing time out
error
BE
Occurs when homing
ILK signal is not turned
ON
Turn ILK signal ON
Defective motor
Replace product
Over speed
C0
Occurred when power
was turned ON
Defective controller
Replace product
Occurs during Cylinder
operation
Defective motor
encoder
Replace product
Servo error
C1
Occurred when power
was turned ON
Defective controller
Replace product
Main power over
voltage
D0
Occurred when power
was ON
Defective controller
Replace product
Occurred when power
was ON
Over voltage of supply
power
Correct supply power
within the specification
Occurs during Cylinder
operation
Over load
Correct the load within
the specification
Regenerative
Voltage error
D1
Occurred when power
was ON
Defective controller
Replace product
Over voltage of supply
power
Correct supply power
within the specification
Occurs during Cylinder
operation
Over load
- Review mechanical
design of customer to
reduce load within the
specification
- Reduce the
acceleration
Incorrect parameter
Check parameter
Deviation counter
error
D8
Occur when power
was turned ON
Defective controller
Replace product
Occurs during Cylinder
operation
Over load
Check load
Cylinder is being
locked
Unlock
Over heat
E0
Occurred when power
was turned ON
Defective controller
Replace product
Occurs during Cylinder
operation
Over load
Check load
High ambient
temperature
Cool down ambient
temperature under 40°C
Shaft is seized
See Below (Action 1)
Содержание SCL Series
Страница 17: ... Dyadic Systems Mechatronics Cylinder Manual MF 005500 EN 17 63 ...
Страница 36: ... Dyadic Systems Mechatronics Cylinder Manual MF 005500 EN 36 63 SCLL5 Model Slider 10Kgf Type ...
Страница 38: ... Dyadic Systems Mechatronics Cylinder Manual MF 005500 EN 38 63 SCLG5 Model Slider High Rigidity Type ...
Страница 44: ... Dyadic Systems Mechatronics Cylinder Manual MF 005500 EN 44 63 External Amplifier SCN6 SCLL SCLT ...
Страница 58: ... Dyadic Systems Mechatronics Cylinder Manual MF 005500 EN 58 63 FT002 for SCN6 ...