Fish the 2C #16 VNTC from the battery box (pre-terminated
and coiled at the battery box) through the pole arm.
•
Connect the 2C #16 VNTC cable to the luminaire, red to red,
black to black using the pre-attached WAGO inline terminals
(Picture below)
•
Attach the luminaire to the pole arm with the supplied set
screws.
•
Install the 2 x 12V, 100AH SLA batteries and secure with the
supplied nylon strap. Connect the batteries in parallel with the
battery jumper cable between the positive (+) and negative (-)
terminals at the back of the battery box. Disconnect the
battery quick connect cable and connect the white lead to the
positive terminal and the black lead to the negative terminal at
the front of the battery box using the ring lugs.
Optional: 24V Lithium Polymer Battery
•
Install 24V, 50 Ah and secure with the supplied nylon
strap. Connect the battery with supplied battery
cable, black banana plug to the (-) terminal and the
red banana plug to the (+) terminal.
TESTING
•
Measure the battery voltage – 23 VDC and higher is
acceptable
•
Measure the open circuit voltage of the solar panel –
29VDC in direct sunlight
•
Connect the battery quick connect cable
•
On the charge controller, the idle LED indicator will
come on. Within 1 minute it will switch to the
discharge LED indicator and the light will come on.
•
In daylight, connect the solar panel to the battery box
using the pre-terminated MC4 connections. The
controller will switch to charging mode and the light
will turn off. At night the controller will continue to
discharge and the light will remain on.