Manual Updates and Information 

 
Every effort is made to supply the latest manual revision with each product. Occasionally a manual 
will be updated between the time your DX Engineering product is shipped and when you receive it. 
Please check the DX Engineering web site (www.dxengineering.com) for the latest revision manual. 

 

Please

 - Take the time to read the entire manual before you start assembly. There are plenty of 

pictures and drawings to see, and if you read the entire manual first, you'll get a better feel for the 
overall construction methods described. Assembly is not difficult, but there are a number of parts 
that must go together in a certain sequence to make assembly easier. 
 

Installation Sequence 

1.

 

Site Selection 

2.

 

Mounting Pipe 

3.

 

Coaxial Cable to Mounting Pipe 

4.

 

Radial System Suggestions 

5.

 

Pivot Base Assembly (US Patent No. 8,130,168) 

6.

 

Mounting Pivot Base to Mounting Pipe  

7.

 

Optional 

DXE-VRW-1

 Manual Winch installation and use 

 
Site Selection 

 

Select a mounting location clear from power lines, structures and other antennas by a minimum of 
78 feet (68 + 10 ft safety rule). 

Consider overhead power lines, utility cables and wires

. The 

further away the vertical is mounted from local noise sources or other metallic objects, which can 
re-radiate noise and affect the tuning, radiation pattern and SWR, the better. Determine the direction 
you want the antenna to pivot and make sure there is adequate clearance (at least 80 feet). 

 

Mounting Pipe 

 

Use a customer supplied 2-1/2" schedule 80, which has an outside diameter (OD) of 2.895", 
galvanized steel thick-walled mounting pipe 

at least

 7-1/2 feet long. This will allow approximately 

4-1/2 feet below ground and 37 inches above ground.  
 
Some manufacturers use the term DOM (drawn over mandrel) which will give you a true OD 
dimension. Other types of mounting pipe may be used but due to lateral strength needed ensure the 
mounting pipe is strong enough. The material most available is ASTM A513 Type 5 which is a 
1020 material. Some pipe suppliers list the material as either 1020 or 1026. Type 1020 has the 
following properties: 
 

ASTM A513 (1020): Up to 2-3/4" OD with maximum wall thickness of 0.25" 
     Tensile: 80,000 PSI.  Yield: 70,000 PSI.  Elongation in 2": 15%.  Rockwell Hardness: B80 
ASTM A513 (1020): Over 2-3/4" OD with wall thickness heavier than 0.25" 
     Tensile: 70,000 PSI.  Yield: 60,000 PSI.  Elongation in 2": 20%.  Rockwell Hardness: B80 

 

3.00" OD x 0.25" wall thickness (or more) of 65,000 PSI yield tubing may also be used. 

Содержание DXE-VA-PIVOT-4

Страница 1: ...E VA PIVOT 4 US Patent No 8 130 168 DXE VA PIVOT 4 INS Revision 0 Shown with Customer Supplied Mounting Pipe DX Engineering 2012 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Tech Support an...

Страница 2: ...es a heavy duty mounting pipe Recommended installation should provide up to 3 OD heavy wall galvanized steel pipe set in concrete Schedule 80 pipe that is called 2 1 2 has an outside diameter of 2 875...

Страница 3: ...y cables and wires The further away the vertical is mounted from local noise sources or other metallic objects which can re radiate noise and affect the tuning radiation pattern and SWR the better Det...

Страница 4: ...ns Fill the hole until the concrete is level with the ground around it Use a level on the mounting pipe as you fill the hole to be sure the mounting pipe is vertically straight Your location landscape...

Страница 5: ...h staples will ensure the wires will not be snagged by mowers people or animals Grass will quickly overgrow the radials and it will be virtually impossible to see them An article describing this proce...

Страница 6: ...t the optional ground radial wires to the DXE RADP 3 Radial Plate as shown in Figure 2 Additional hardware kits are available DXE RADP 1HWK that contain 20 sets of Radial Plate Hardware There are opti...

Страница 7: ...6 Overall Super Duty Pivot Base US Patent No 8 130 168 Assembly Reference Drawing The 3 Mounting Pipe and 4 Antenna Base Section are Customer Supplied Feedpoint hardware shown for reference only...

Страница 8: ...ur 3 8 hex nuts Assemble the bottom hinge to the bottom of the heavy duty Extren insulated channel as shown below Tighten the hardware 3 Locate the three 4 Cast Saddle Clamps three 4 x 3 8 x 6 813 lon...

Страница 9: ...eavy duty Extren insulated channel as shown below Tighten the hardware 5 Locate the stainless steel base side bottom hinge two 1 2 13 x 1 3 4 long stainless steel hex head bolts two pivot bushings fou...

Страница 10: ...the end of the hex nuts the two U Bolts to the stainless steel base side bottom hinge as shown below The U Bolts will be tightened in a later assembly step 7 Locate the stainless steel Pivot Base Winc...

Страница 11: ...two U Bolts to the Pivot Base Winch Mount as shown below The U Bolts will be tightened in a later assembly step 9 Locate four 3 8 16 x 1 1 4 long stainless steel hex bolts eight stainless steel 3 8 fl...

Страница 12: ...unting pipe to the bottom side of the winch mounting plate Position the base fixture in the position you pre selected for the pivoting direction Straighten out the U Bolts perpendicular to the mountin...

Страница 13: ...through the three U Bolts with the feed point at the bottom facing front as shown below The bottom of your 4 OD element tube should be even with the bottom of the insulated channel as shown below Tigh...

Страница 14: ...x nuts the two U Bolts and associated hardware to the antenna hook mounting plate as shown below The U Bolts will be tightened in the next assembly step 13 Loosen the U Bolts enough to slide the Anten...

Страница 15: ...ainless steel hex bolts six stainless steel 3 8 16 flat washers and three 3 8 16 Stainless Steel Nyloc Nuts Loosely install the three sets of stainless steel hardware on the manual winch as shown belo...

Страница 16: ...nce extended weathering and sunlight may damage or weaken the strap Refer to the manual that is included with the DXE VRW 1 Manual Winch for details 3 To lower the antenna ensure the winch hook is in...

Страница 17: ...nd Optional Manual Winch Note Sawhorses chairs or ladders should be used to support the vertical sections during assembly with the pivot base and whenever the vertical is tilted down to allow easy mai...

Страница 18: ...er or Utility Lines Can Be Lethal Suggested Feedline Connection The easiest way to make a reliable feedline connection using customer supplied coaxial cable is using the optional DXE RADP 3 Radial Pla...

Страница 19: ...xtren Insulator 10 x 1 2 x 29 625 6 Saddle Backing Plate 1 5 x 375 x 8 1 4 Antenna Pivot Hook Mount 1 4 Pivot Base Winch Mount 2 Pivot Base Plate Bracket 1 4 Pivot Base Lock Plate 2 Backing Plate 2 4...

Страница 20: ...8 x 6 813 Stainless Steel U Bolt 12 5 4 Cast Saddle Clamp 13 42 3 8 Flat Washer 14 34 3 8 Split Lock Washer 15 34 3 8 16 Nut 16 8 3 8 16 x 1 375 Long Hex Head Cap Screw 17 4 3 Cast Saddle 18 4 3 x 3...

Страница 21: ...e securely by biting into the surface For this reason it is not recommended for softer aluminum tubing or pipe U Bolt thread dimensions 3 8 16 x 1 75 V bolt and saddle made from high strength 18 8 sta...

Страница 22: ...ll lay flat as you place it on the ground easy to install The twenty 65 foot pre cut radial wires include 1 4 ring terminals professionally crimped on one end for quick and easy attachment to the radi...

Страница 23: ...22 NOTES...

Страница 24: ...tive by reason of improper installation damaged from severe weather including floods or abnormal environmental conditions such as prolonged exposure to corrosives or power surges or by the performance...

Отзывы: